Parameters
Parameter list
1-264
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the signal source for speed setpoint 2.
The sum from CI: p2151 and CI: p2154 is used for the following messages:
"Speed setpoint - actual value deviation within tolerance t_off" (BO: r2197.7)
"Speed setpoint - actual value deviation within tolerance t_on" (BO: r2199.4)
Ramp-up/ramp-down completed (BO: r2199.5)
Dependency:
Refer to: p2151, r2197, r2199
Description:
Sets the speed/velocity threshold value for the following messages:
"|n_act| < = speed threshold value 2" (BO: r2197.1)
"|n_act| < speed threshold value 2" (BO: r2197.2)
Dependency:
Refer to: p2140, r2197
Description:
Sets the delay time for the signal "comparison value reached" (BO: r2199.1).
Dependency:
Refer to: p2141, p2142, r2199
Description:
Sets the speed/velocity threshold value for the signal "|n_act| < speed threshold value 3" (BO: r2199.0).
Dependency:
Refer to: p2150, r2199
Description:
Sets the hysteresis speed/velocity (bandwidth) for the signal "n_act > n_max" (BO: r2197.6).
p2154[0...n]
CI: Speed setpoint 2 / n_set 2
VECTOR
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
CDS
Function diagram:
8010
P-Group:
Messages
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p2155[0...n]
Speed threshold 2 / n_thresh val 2
VECTOR
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
0.00 [1/min]
210000.00 [1/min]
900.00 [1/min]
p2156[0...n]
On delay, comparison value reached / t_on cmpr val rchd
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0.0 [ms]
10000.0 [ms]
0.0 [ms]
p2161[0...n]
Speed threshold 3 / n_thresh val 3
VECTOR
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
0.00 [1/min]
210000.00 [1/min]
5.00 [1/min]
p2162[0...n]
Hysteresis speed n_act > n_max / Hyst n_act>n_max
VECTOR
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
8010
P-Group:
Messages
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
0.00 [1/min]
60000.00 [1/min]
600.00 [1/min]
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...