![Siemens SINAMICS G Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180037.webp)
Parameter list
Parameters
1-37
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the actual speed/velocity setpoint after the setpoint filters.
Description:
Displays the actual smoothed speed/velocity actual value for the speed/velocity control.
Dependency:
Refer to: r0021
Note:
This value is calculated in sensorless operation and for V/f control.
For closed-loop vector control, the value in r0063 can be smoothed again and displayed in r1445.
The value displayed in r0021 is the smoothed value of r0063.
Description:
Displays the actual control difference of the speed/velocity controller.
Note:
In the servo control mode with active reference model, the system deviation to the P component of the speed/veloc-
ity controller is displayed.
Description:
Displays the slip frequency for induction motors.
Description:
Displays the motor module output frequency.
r0062
CO: Speed setpoint after the filter / n_set after filter
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
1590,
1750, 5020, 5030, 5210, 6030
P-Group:
Displays, signals
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
- [1/min]
- [1/min]
- [1/min]
r0063
CO: Actual speed, smoothed / n_act smooth
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
1580,
1590, 4710, 6010, 6040, 8010
P-Group:
Displays, signals
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
- [1/min]
- [1/min]
- [1/min]
r0064
CO: Speed controller system deviation / n_ctrl system dev
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
5040,
6040
P-Group:
Displays, signals
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
- [1/min]
- [1/min]
- [1/min]
r0065
Slip frequency / f_Slip
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
6310,
6730
P-Group:
Displays, signals
Units group:
FREQUENCY
Unit selection:
-
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
r0066
CO: Drive output frequency / Drv f_output
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
1690,
5300, 5730, 6310, 6730, 6731
P-Group:
Displays, signals
Units group:
FREQUENCY
Unit selection:
-
Min Max
Factory
setting
- [Hz]
- [Hz]
- [Hz]
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...