Parameters
Parameter list
1-312
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the physical address where the function generator is to be connected.
Dependency:
Only effective when p4810 = 99.
Description:
Sets the reference value for 100 % for referred inputs.
Dependency:
Only effective when p4810 = 99.
Description:
Selects the required drive where the function generator is to be connected.
Only one SERVO type drive can be selected.
Index:
[0] = First drive for connection
[1] = Second drive for connection
Dependency:
Only effective when p4810 = 1, 2, 3, 4 or 5.
Description:
Displays the output signal for the function generator.
Dependency:
Refer to: p4810
Note:
The value is displayed independently of the function generator mode.
The signal is available as connector output for an ongoing interconnection.
Description:
Sets the signal to be generated for the function generator.
p4812
Function generator physical address / FG phys address
CU
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 4294967295
0
p4813
Function generator physical address reference value / FG phys addr ref
CU
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Min Max
Factory
setting
1.00 1000000.00
1.00
p4815[0...1]
Function generator drive number / FG drive number
CU
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 65535
0
r4818
CO: Function generator output signal / FG output signal
CU
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Trace and function generator
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
p4820
Function generator signal shape / FG signal shape
CU
Can be changed:
U, T
Access level:
3
Data type:
Integer16
Data set:
-
Function diagram:
-
P-Group:
Trace and function generator
Units group:
-
Unit selection:
-
Min Max
Factory
setting
1 5
1
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...