Function diagrams
Internal control/status words
2-418
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Picture 2-40 2537 – Status word monitoring functions 3
- 2537 -
8
7
6
5
4
3
2
1
fp_S01_2537_en.vsd
DO: VECTOR
SINAMICS G
17.12.04
V02.02.00
Internal control/status words - status word, monitoring functions 3
11
12
13
14
15
1 = |n_act| < speed threshold value 3
(p2161)
Status word, monitoring functions
3
1 = f or n comparison value reached or exceeded
(p2141)
Reserved
Reserved
1 = Speed setpoint - actual value deviation within tolerance t_on
1 = Ramp-up/ramp-down complet
e
d
0 = Ramp-function generator active
Reserved
Reserved
Reserved
Reserved
Reserved
1 = Torque utilization < torque threshold value 2 (p2194)
Reserved
Reserved
Reserved
Reserved
PROFIdrive b
it
9
10
8
7
6
5
4
3
2
1
0
Bit No.
4000.00 µs
From torque signals [8012.5]
From speed signals [8010.7]
From speed signals [8010.5]
From speed signals [8010.4]
r2199
ZSW monitoring functions 3
r2199.11
r2199.5
r2199.1
r2199.0
<1>
<1>n_act = smoothed speed actual value r2169 [8010.2].
[8012.1]
From speed signals [8010.8]
r2199.4
Function diagram
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...