![Siemens SINAMICS G Скачать руководство пользователя страница 214](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180214.webp)
Parameters
Parameter list
1-214
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the absolute value of the flux of the motor model.
Description:
Sets the configuration for the adaptation circuit of the motor model:
Induction motor: Rs, Lh and offset compensation.
Permanent-magnet synchronous motor: kT
Description:
Sets the integral action time for the Rs adaptation of the motor model of the induction motor.
Description:
Displays the correction value for the Rs adaptation of the motor model for the induction motor.
Description:
Sets the proportional gain for the Rs adaptation of the motor model of the induction motor.
r1779
Motor model absolute flux / MotMod abs flux
VECTOR (n/M)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
p1780[0...n]
Motor model configuration adaptation / MotMod config adap
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Unsigned8
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0000 bin
0001 1110 bin
0001 1100 bin
Bit field:
Bit
Signal name
0 signal
1 signal
FP
01
Select motor model IM Rs adaptation
No
Yes
-
02
Select motor model IM Lh adaptation
No
Yes
-
03
Select motor model PESM KT adaptation
No
Yes
-
04
Select motor model, offset adaptation
No
Yes
-
p1781[0...n]
Motor model IM Rs adaptation integral action time / MotMod Rs Tn
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
TIME_M3
Unit selection:
p0528
Min Max
Factory
setting
10 [ms]
10000 [ms]
100 [ms]
r1782
Motor model IM Rs adaptation correction value / MotMod Rs corr
VECTOR (n/M)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
RESISTANCE
Unit selection:
-
Min Max
Factory
setting
- [Ohm]
- [Ohm]
- [Ohm]
p1783[0...n]
Motor model IM Rs adaptation Kp / MotMod Rs Kp
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0.000 1.000
0.100
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...