![Siemens SINAMICS G Скачать руководство пользователя страница 409](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180409.webp)
PROFIBUS
Function diagrams
2-409
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Picture 2-32 2483 – Send telegram free interconnection via BICO (p0922 = 999)
- 2483 -
8
7
6
5
4
3
2
1
fp_S01_2483_de.vsd
DO: CU320, TB30, TM31
SINAMICS G
17.12.04
V02.02.00
PROFIBUS - send telegram, free interconnection via BICO (p0922 = 999)
PROFIBUS send words 1...5
Diagnostics display
r2053[0...4]
...
PZD send word 1
PZD send word 2
PZD send word 3
PZD send word 4
PZD send word 5
<1>
(0)
p2051[1]
(0)
p2051[2]
(0)
p2051[3]
(0)
p2051[4]
(0)
p2051[0]
Reference quantities for ongoing interconnection
p200x
<2>
PROFIBUS sampling time
Refer to [1020.7]
<1>
Using the binector/connector converters at [2472], bits of 4 send words can be interconnected with any binector
s
.
<2>
Physical word quantities are inserted in the telegram as referenced quantities. In this case, p200x is decisive as reference
quantity (telegram
contents = 4000 hex if the input quantity has the value p200x).
PROFIBUS send telegram
X126
PROFIBUS
Drive object
Header
Trailer
Function diagram
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...