![Siemens SINAMICS G Скачать руководство пользователя страница 207](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180207.webp)
Parameter list
Parameters
1-207
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the actual output of the Isq current controller (torque/force generating current, PI controller). The value
contains the proportional and integral components of the PI controller.
Description:
Displays the integral component of the Isq current controller (torque/force-generating current, PI controller).
Description:
Displays the actual output of the Isd current controller (flux-generating current, PI controller). The value contains the
proportional and integral components of the PI controller.
Description:
Displays the integral component of the Isd current controller (flux-generating current, PI controller).
Description:
Displays the limit value for the integral component of the Isd current controller.
Description:
Sets the scaling of the quadrature arm decoupling
r1718
CO: Isq controller output / Isq_ctrl outp
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
6714
P-Group:
Control
Units group:
VOLTAGE_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Veff]
- [Veff]
- [Veff]
r1719
Isq controller integral component / Isq_ctrl I_comp
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
VOLTAGE_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Veff]
- [Veff]
- [Veff]
r1723
CO: Isd controller output / Isd_ctrl output
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
6714
P-Group:
Control
Units group:
VOLTAGE_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Veff]
- [Veff]
- [Veff]
r1724
Isd controller integral component / Isd_ctrl I_comp
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
VOLTAGE_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Veff]
- [Veff]
- [Veff]
r1725
Isd controller integral component limit / Isd_ctrl I_limit
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
-
P-Group:
Control
Units group:
VOLTAGE_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Veff]
- [Veff]
- [Veff]
p1726[0...n]
Quadrature arm decoupling, scaling / Transv_decpl scal
VECTOR (n/M)
Can be changed:
U, T
Access level:
4
Data type:
Floating Point
Data set:
DDS
Function diagram:
-
P-Group:
Control
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
0.0 [%]
200.0 [%]
75.0 [%]
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...