Parameter list
Parameters
1-281
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Note:
p2280 = 0: The proportional gain is disabled.
Description:
Sets the integral actual time (I component, integrating time constant) of the technology controller.
Note:
p2285 = 0: The integral action time is disabled.
Description:
Sets the signal source for the pre-control signal of the technology controller.
Description:
Sets the maximum limit of the technology controller.
Dependency:
Refer to: p2292
Caution!
The maximum limit must always be greater than the minimum limit (p2291 > p2292).
Description:
Sets the minimum limit of the technology controller.
Dependency:
Refer to: p2291
Caution!
The maximum limit must always be greater than the minimum limit (p2291 > p2292).
Description:
Sets the ramp-up and ramp-down time for the maximum and minimum limiting (p2291 and p2292) of the technology
controller.
Dependency:
Refer to: p2291, p2292
Note:
The ramp-up/ramp-down times are referred to 100 %.
p2285
Technology controller integral action time / Tec_ctr Tn
VECTOR (Tech ctrl)
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
-
Function diagram:
7958
P-Group:
Technology
Units group:
TIME
Unit selection:
-
Min Max
Factory
setting
0.000 [s]
60.000 [s]
0.000 [s]
p2289[0...n]
CI: Technology controller pre-control signal / Tec_ctr prectrl
VECTOR (Tech ctrl)
Can be changed:
U, T
Access level:
2
Data type:
Unsigned32
Data set:
CDS
Function diagram:
7958
P-Group:
Technology
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p2291
Technology controller maximum limiting / Tec_ctr max_limit
VECTOR (Tech ctrl)
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
-
Function diagram:
7958
P-Group:
Technology
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
100.00 [%]
p2292
Technology controller minimum limiting / Tec_ctr min_lim
VECTOR (Tech ctrl)
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
-
Function diagram:
7958
P-Group:
Technology
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
-200.00 [%]
200.00 [%]
0.00 [%]
p2293
Technology controller ramp-up/ramp-down time / Tec_ctr ramp up/dn
VECTOR (Tech ctrl)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
7958
P-Group:
Technology
Units group:
TIME
Unit selection:
-
Min Max
Factory
setting
0.00 [s]
100.00 [s]
1.00 [s]
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...