![Siemens SINAMICS G Скачать руководство пользователя страница 185](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180185.webp)
Parameter list
Parameters
1-185
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Dependency:
Refer to: r1119, p1155, p1160
Description:
Displays the smoothed actual speed for speed control.
Description:
Sets the smoothing time for the actual speed for sensorless closed-loop speed control.
Note:
The smoothing must be increased if there is gear backlash. For longer smoothing times, the integral action time of
the speed controller must also be increased (e.g. using p0340 = 4).
Description:
Displays the system deviation of the I component of the speed/velocity controller.
When the reference model is inactive ((1433 = 0 Hz), this parameter corresponds to the system deviation of the
complete PI controller (r1454 = r0064).
Description:
Sets the source for the adaptation signal to additionally adapt the P gain of the speed/velocity controller.
Dependency:
Refer to: p1456, p1457, p1458, p1459
Description:
Sets the lower starting point of the adaptation range for the additional adaptation of the P gain of the speed/velocity
controller. The values are in % and refer to the set source of the adaptation signal.
Dependency:
Refer to: p1455, p1457, p1458, p1459
r1445
CO: Actual speed, smoothed / n_act smooth
VECTOR (n/M)
Can be changed:
-
Access level:
4
Data type:
Floating Point
Data set:
-
Function diagram:
6040
P-Group:
Control
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
- [1/min]
- [1/min]
- [1/min]
p1452[0...n]
Speed actual value smoothing time (SLVC) / n_act T_smoothSLVC
VECTOR (n/M)
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
DDS
Function diagram:
6040
P-Group:
Control
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
0.00 [ms]
32000.00 [ms]
10.00 [ms]
r1454
CO: Speed controller system deviation I component / n_ctrl sys_dev Tn
VECTOR (n/M)
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
5040
P-Group:
Control
Units group:
SPEED_ROT
Unit selection:
-
Min Max
Factory
setting
- [1/min]
- [1/min]
- [1/min]
p1455[0...n]
CI: Speed controller P gain adaptation signal / n_ctrl Adpt_sig Kp
VECTOR (n/M)
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
CDS
Function diagram:
5050,
6050
P-Group:
Control
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p1456[0...n]
Speed controller P gain adaptation lower starting point / n_ctrl AdaptKpLow.
VECTOR (n/M)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
DDS
Function diagram:
5050,
6050
P-Group:
Control
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
0.00 [%]
400.00 [%]
0.00 [%]
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...