![Siemens SINAMICS G Скачать руководство пользователя страница 643](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180643.webp)
List of faults and alarms
Faults and Alarms
3-643
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Reaction upon N:
NONE
Acknowledge
upon N:
NONE
A34904 (F, N)
VSM: EEPROM
Reaction:
NONE
Acknowledge:
NONE
Cause:
An error has occurred accessing the non-volatile memory on the terminal module.
Remedy:
Replace the terminal module.
Reaction upon F:
NONE
Acknowledge
upon F:
IMMEDIATELY (power on)
Reaction upon N:
NONE
Acknowledge
upon N:
NONE
A34905 (F, N)
VSM: Parameter access
Reaction:
NONE
Acknowledge:
NONE
Cause:
The control unit attempted to write an illegal parameter value into the voltage sensing module (VSM).
Remedy:
- check whether the firmware version of the VSM (r0158) matches the firmware version of control unit (r0018).
- if required, replace the voltage sensing module.
Note:
The firmware versions that match each other are in the readme.txt file on the CompactFlash Card.
Reaction upon F:
NONE
Acknowledge
upon F:
IMMEDIATELY (power on)
Reaction upon N:
NONE
Acknowledge
upon N:
NONE
A34920 (F, N)
VSM: Temperature sensor fault
Reaction:
NONE
Acknowledge:
NONE
Cause:
When evaluating the temperature sensor, an error occurred.
Alarm value (r2124, decimal):
1: Wire breakage or sensor not connected (KTY: R > 1630 Ohm).
2: Measured resistance too low (PTC: R < 30 Ohm, KTY: R < 340 Ohm).
Remedy:
- check that the sensor is connected correctly.
- replace sensor.
Reaction upon F:
NONE
Acknowledge
upon F:
IMMEDIATELY (power on)
Reaction upon N:
NONE
Acknowledge
upon N:
NONE
A34999 (F, N)
VSM: Unknown alarm
Reaction:
NONE
Acknowledge:
NONE
Cause:
A fault occurred on the voltage sensing module (VSM) an alarm has occurred that cannot be interpreted by the con-
trol unit firmware.
This can occur if the firmware on the module is more recent than the firmware on the control unit.
Alarm value (r2124, decimal):
Alarm number.
If required, the significance of this new alarm can be referred to in a more recent description of the control unit.
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...