Parameter list
Parameters
1-127
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the system runtime in milliseconds when the fault occurred.
Dependency:
Refer to: r0945, r0947, r0949, r2109, r2114, r2130, r2133, r2136
Description:
Displays additional information about the fault that occurred (as integer number).
Dependency:
Refer to: r0945, r0947, r0948, r2109, r2130, r2133, r2136
Description:
Lists parameters assigned to a fault.
Dependency:
Refer to: r0946
Description:
Number of fault situations that have occurred since the last reset.
Dependency:
The fault buffer is deleted (cleared) by setting p0952 to 0.
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136
r0948[0...63]
Fault time received in milliseconds / t_fault recv ms
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
1750,
8060
P-Group:
Messages
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r0949[0...63]
Fault value / Fault value
All objects
Can be changed:
-
Access level:
3
Data type:
Integer32
Data set:
-
Function diagram:
1750,
8060
P-Group:
Messages
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r0951[0...65534] Fault number list / Fault number list
All objects
Can be changed:
-
Access level:
4
Data type:
Unsigned16
Data set:
-
Function diagram:
8060
P-Group:
Messages
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
p0952
Fault cases, counter / Fault cases No.
All objects
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
1710,
8060
P-Group:
Messages
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 65535
0
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...