Parameter list
Parameters
1-355
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the Safety Integrated status on the motor module.
Dependency:
Refer to: r9772
Description:
Displays the cycle time for the safety functions on the motor module.
Dependency:
Refer to: r9780
Description:
Displays the number of the data that are being presently compared crosswise on the motor module.
Example:
r9894[0] = 1 (monitoring clock cycle)
r9894[1] = 2 (enable safety-related functions)
r9894[2] = 3 (tolerance time, SGE changeover)
r9894[3] = 4 (transition time, STOP F to STOP A)
r9894[4] = 0
...
r9894[19] = 0
The data corresponding to the numbers 1, 2, 3 and 4 are subject to a crosswise comparison.
Dependency:
Refer to: r9794
Note:
The complete list of numbers for crosswise data comparison is listed in Fault F30611.
Description:
Displays the number of the cross-checked data which has caused STOP F on the motor module.
r9872
CO/BO: SI status list (motor module) / SI status MM
VECTOR
Can be changed:
-
Access level:
2
Data type:
Unsigned32
Data set:
-
Function diagram:
2804
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
SH on selected on motor module
No
Yes
2810
01
SH on motor module active
No
Yes
2810
04
SBC requested
No
Yes
2814
09
STOP A cannot be acknowledged, active
No
Yes
2802
10
STOP A active
No
Yes
2802
15
STOP F active
No
Yes
2802
r9880
SI monitoring clock cycle (motor module) / SI monitor_clck MM
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
2802
P-Group:
Safety Integrated
Units group:
TIME_M3
Unit selection:
-
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
r9894[0...19]
SI crosswise comparison list (motor module) / SI KDV_list MM
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
2802
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r9895
SI diagnostics for STOP F (motor module) / SI diag STOP F MM
VECTOR
Can be changed:
-
Access level:
2
Data type:
Unsigned32
Data set:
-
Function diagram:
2802
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...