Parameter list
Parameters
1-105
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the motor operating time for the appropriate drive.
The motor operating time counter is started when the pulses are enabled. When the pulse enable is withdrawn, the
counter is held and the value saved. The persistence is in the NVRAM - this means that if the module is equipped
with an NVRAM, the value is saved in a non-volatile fashion; otherwise not.
If p0651 is at 0, the counter is de-activated.
Display in hours.
Dependency:
Refer to: p0651
Refer to: F01590
Note:
The value in p0650 can only be reset to 0.
Description:
Sets the service/maintenance intervals for the appropriate drive.
If the selected motor operating time is reached (p0650), then the appropriate fault is output.
Display in hours.
Dependency:
Refer to: p0650
Refer to: F01590
Note:
For p0651 = 0 [h], the motor operating time counter is disabled.
Description:
Runs the appropriate ACX file on the CompactFlash Card.
The binector inputs (BI) of the appropriate command data set (CDS) are appropriately interconnected.
The selected ACX file must be located in the following directory:
... /PMACRO/<drive object>/P700/PMxxxxxx.ACX
Example:
p0700 = 6 --> the file PM000006.ACX is run.
Dependency:
The ACX file to be run must be created according to the definition for ACX macros and must be saved in the direc-
tory intended on the CompactFlash Card.
Refer to: p0015, p1000, p1500
Note:
BI: Binector input
p0650[0...n]
Actual motor operating time / t_motor actual
VECTOR
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
MDS
Function diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 4294967295
0
p0651[0...n]
Motor operating time service interval / t_motor service
VECTOR
Can be changed:
T
Access level:
3
Data type:
Unsigned32
Data set:
MDS
Function diagram:
-
P-Group:
Motor
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 99999
0
p0700[0...n]
Macro binector input (BI) / Macro BI
VECTOR
Can be changed:
C2, T
Access level:
1
Data type:
Unsigned32
Data set:
CDS
Function diagram:
-
P-Group:
Commands
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 999999
0
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...