![Siemens SINAMICS G Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180041.webp)
Parameter list
Parameters
1-41
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Displays the torque-generating current actual value (Iq_act).
Dependency:
Refer to: r0030
Note:
This value is irrelevant for the V/f control mode.
The torque-generating current actual value is available smoothed (r0030 with 300 ms) and unsmoothed (r0078).
Description:
Displays the torque/force setpoint at the output of the speed/velocity controller (before clock cycle interpolation).
Description:
Displays the actual torque/force actual value.
Dependency:
Refer to: r0031
Note:
The active current actual value is available smoothed (r0031) and unsmoothed (r0080).
Description:
Displays the torque/force utilization as a percentage.
The torque/force utilization is obtained from the required smoothed torque/force referred to the torque/force limit.
Dependency:
Refer to: r0033
Note:
The torque utilization is available smoothed (r0033) and unsmoothed (r0081).
r0078
CO: Current actual value, torque-generating / Iq_act
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
6310,
6714
P-Group:
Displays, signals
Units group:
CURRENT_AC_EFF
Unit selection:
-
Min Max
Factory
setting
- [Aeff]
- [Aeff]
- [Aeff]
r0079
CO: Torque setpoint total / M_set total
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
1710,
6030, 6060, 6710
P-Group:
Displays, signals
Units group:
TORQUE
Unit selection:
-
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
r0080
CO: Torque actual value / M_act
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
5730,
6714
P-Group:
Displays, signals
Units group:
TORQUE
Unit selection:
-
Min Max
Factory
setting
- [Nm]
- [Nm]
- [Nm]
r0081
CO: Torque utilization / M_Utilization
VECTOR
Can be changed:
-
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
8012
P-Group:
Displays, signals
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...