Parameters
Parameter list
1-354
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Note:
For a crosswise data comparison between p9650 and p9850, a difference of one Safety monitoring clock cycle is
tolerated.
The parameterized time is internally rounded-off to an integer multiple of the monitoring clock cycle.
SGE: Safety-related input signal (e.g. SH terminals)
Description:
Sets the transition period from STOP F to STOP A on the motor module.
Dependency:
Refer to: p9658, r9895
Refer to: F30611
Note:
For a crosswise data comparison between p9658 and p9858, a difference of one Safety monitoring clock cycle is
tolerated.
The parameterized time is internally rounded-off to an integer multiple of the monitoring clock cycle.
STOP F: Defect in a monitoring channel (error in the crosswise data comparison)
STOP A: Pulse cancellation via the safety shutdown path
Description:
Displays the Safety Integrated version on the motor module.
Index:
[0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
Dependency:
Refer to: r9770
Note:
Example:
r9870[0] = 2, r9870[1] = 1, r9870[2] = 1 --> Safety version V02.01.01
Description:
Displays the safety integrated monitoring functions supported on the control unit and motor module.
The motor module determines this display.
Dependency:
Refer to: r9771
Note:
MM: Motor module
SBC: Safe brake control
SH: Safe standstill
SI: Safety Integrated
p9858
SI transition time STOP F to STOP A (control unit) / SI STOP F to A MM
VECTOR
Can be changed:
C2
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
2802
P-Group:
Safety Integrated
Units group:
TIME_M6
Unit selection:
-
Min Max
Factory
setting
0.00 [µs]
30000000.00 [µs]
0.00 [µs]
r9870[0...2]
SI version (motor module) / SI version MM
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
2802
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
r9871
SI common functions (motor module / SI general fct MM
VECTOR
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
2804
P-Group:
Safety Integrated
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
SH supported via terminal
No
Yes
-
01
SBC supported
No
Yes
-
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...