Parameters
Parameter list
1-278
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Sets the signal source for the setpoint 1 of the technology controller.
Dependency:
Refer to: p2254, p2255
Description:
Sets the signal source for the setpoint 2 of the technology controller.
Dependency:
Refer to: p2253, p2256
Description:
Sets the scaling for the setpoint 1 of the technology controller.
Dependency:
Refer to: p2253
Description:
Sets the scaling for the setpoint 2 of the technology controller.
Dependency:
Refer to: p2254
Description:
Sets the ramp-up time of the technology controller.
Dependency:
Refer to: p2258
Note:
The ramp-up time is referred to 100 %.
p2253[0...n]
CI: Technology controller setpoint 1 / Tec_ctr setpoint 1
VECTOR (Tech ctrl)
Can be changed:
U, T
Access level:
2
Data type:
Unsigned32
Data set:
CDS
Function diagram:
7958
P-Group:
Technology
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p2254[0...n]
CI: Technology controller setpoint 2 / Tec_ctr setpoint 2
VECTOR (Tech ctrl)
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32
Data set:
CDS
Function diagram:
7958
P-Group:
Technology
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p2255
Technology controller setpoint 1 scaling / Tec_ctr set1 scal.
VECTOR (Tech ctrl)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
7958
P-Group:
Technology
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
0.00 [%]
100.00 [%]
100.00 [%]
p2256
Technology controller setpoint 2 scaling / Tec_ctr set2 scal.
VECTOR (Tech ctrl)
Can be changed:
U, T
Access level:
3
Data type:
Floating Point
Data set:
-
Function diagram:
7958
P-Group:
Technology
Units group:
PERCENT
Unit selection:
-
Min Max
Factory
setting
0.00 [%]
100.00 [%]
100.00 [%]
p2257
Technology controller, ramp-up time / Tec_ctr t_ramp-up
VECTOR (Tech ctrl)
Can be changed:
U, T
Access level:
2
Data type:
Floating Point
Data set:
-
Function diagram:
7958
P-Group:
Technology
Units group:
TIME
Unit selection:
-
Min Max
Factory
setting
0.00 [s]
650.00 [s]
1.00 [s]
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...