![Siemens SINAMICS G Скачать руководство пользователя страница 249](http://html.mh-extra.com/html/siemens/sinamics-g/sinamics-g_list-manual_378180249.webp)
Parameter list
Parameters
1-249
Siemens AG 2004 All Rights Reserved
SINAMICS G List Manual, Edition 12.2004
Description:
Setting to invert the individual binector outputs of the connector-binector converter.
Using p2098[0], the signals of CI: p2099[0] are influenced.
Using p2098[1], the signals of CI: p2099[1] are influenced.
Dependency:
Refer to: r2094, r2095, p2099
Note:
Bit x = 1: Inverts the appropriate binector output.
Bit x = 0: No inversion.
Description:
Selects a PROFIBUS PZD receive word for bit-serial interconnection.
Dependency:
Refer to: r2094, r2095
Note:
p2099 together with r2094 and r2095 forms two connector-binector converters:
Connector input p2099[0] to binector outputs in r2094
Connector input p2099[1] to binector outputs in r2094
Description:
Selects the faults for which the fault response should be changed
Dependency:
The fault is selected and the required response is set under the same index.
Refer to: p2101
p2098[0...1]
Invert connector-binector converter bit-serial / CI_BO conv inv
All objects
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
2460
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0000 bin
1111 1111 1111 1111 bin
0000 bin
Bit field:
Bit
Signal name
0 signal
1 signal
FP
00
Bit 0
Not inverted
Inverted
-
01
Bit 1
Not inverted
Inverted
-
02
Bit 2
Not inverted
Inverted
-
03
Bit 3
Not inverted
Inverted
-
04
Bit 4
Not inverted
Inverted
-
05
Bit 5
Not inverted
Inverted
-
06
Bit 6
Not inverted
Inverted
-
07
Bit 7
Not inverted
Inverted
-
08
Bit 8
Not inverted
Inverted
-
09
Bit 9
Not inverted
Inverted
-
10
Bit 10
Not inverted
Inverted
-
11
Bit 11
Not inverted
Inverted
-
12
Bit 12
Not inverted
Inverted
-
13
Bit 13
Not inverted
Inverted
-
14
Bit 14
Not inverted
Inverted
-
15
Bit 15
Not inverted
Inverted
-
p2099[0...1]
CI: PROFIBUS PZD selection receive bit-serial / Select CO_BO conv
All objects
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32
Data set:
-
Function diagram:
2460
P-Group:
Communication
Units group:
-
Unit selection:
-
Min Max
Factory
setting
- -
0
p2100[0...19]
Setting the fault number for fault response / F_no F response
All objects
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Data set:
-
Function diagram:
1750,
8075
P-Group:
Messages
Units group:
-
Unit selection:
-
Min Max
Factory
setting
0 65535
0
Содержание SINAMICS G
Страница 1: ...List Manual 12 2004 Edition sinamics SINAMICS G ...
Страница 2: ......
Страница 8: ...Preface Preface 8 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 680: ...List of Abbreviations Abbreviations 680 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 686: ...References References 686 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...
Страница 696: ...Index Index 696 Siemens AG 2004 All Rights Reserved SINAMICS G List Manual Edition 12 2004 ...