2 Parameters
2.2 List of parameters
SINAMICS DCP
274
List Manual (LH21), 05/2016
Description:
Sets the operating mode of the MPP tracker.
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Sets the interval for plotting the characteristic of the PV array.
This parameter is only active in operating mode p54030.0 = 1.
Dependency:
Refer to: p54030
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Sets the duration for plotting the characteristic of the PV array.
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Sets the search range of the MPP tracker.
The MPP tracker searches for the MPP each time that the PV array characteristic is plotted. Starting from this point,
the MPP tracker continually changes the current setpoint to identify the point with the maximum power. The search
range (i.e. the permissible current setpoint) is limited to the following range:
Current setpoint for the MPP according to the characte/- at the value set using this parameter.
Note:
MPP: maximum power point (point along the characteristic with the maximum power)
Description:
Displays the current values of the last PV array characteristic that was plotted.
p54030
MPP tracker operating mode / MPPT op_mode
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32
Func. diagram:
6700
Min Max
Factory
setting
- -
0001
bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
PV array characteristic plot time controlled
Yes
No
6700
01
PV array characteristic plot at search range
limits
Yes
No
6700
02
Reserved
Yes
No
-
03
Reserved
Yes
No
-
p54035
MPP tracker characteristic plot interval / MPPT char interval
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
60 [s]
3600 [s]
300 [s]
p54036
MPP tracker characteristic plot duration / MPPT char dur
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
1 [s]
60 [s]
10 [s]
p54037
MPP tracker current search range / MPPT I srch range
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
1.00 [%]
100.00 [%]
10.00 [%]
r54040[0...31]
MPP tracker characteristic current / MPPT char I
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6700
Min Max
Factory
setting
- [A]
- [A]
- [A]
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...