2 Parameters
2.2 List of parameters
SINAMICS DCP
216
List Manual (LH21), 05/2016
Description:
Setting to invert the individual binector outputs of the connector-binector converter.
Using p8898[0], the signals of CI: p8899[0] are influenced.
Using p8898[1], the signals of CI: p8899[1] are influenced.
Dependency:
Refer to: r8894, r8895, p8899
Description:
Sets the signal source for the connector-binector converter.
A PZD receive word can be selected as signal source. The signals are available to be serially passed-on
(interconnection).
Dependency:
Refer to: r8850, r8894, r8895, p8898
Note:
From the signal source set via the connector input, the corresponding lower 16 bits are converted.
p8899[0...1] together with r8894.0...15 and r8895.0...15 forms two connector-binector converters:
Connector input p8899[0] to binector output in r8894.0...15
Connector input p8899[1] to binector output in r8895.0...15
Description:
Displays the PROFINET Device ID.
Every SINAMICS device type has its own PROFINET Device ID and its own PROFINET GSD.
Note:
List of the SINAMICS Device IDs:
0501 hex: S120/S150
0504 hex: G130/G150
050A hex: DC MASTER
050C hex: MV
050F hex: G120P
0510 hex: G120C
0511 hex: G120 CU240E-2
p8898[0...1]
IF2 invert connector-binector converter binector output / Con/bin outp inv
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Func. diagram:
2485, 2491
Min Max
Factory
setting
-
-
0000 0000 0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Bit 0
Inverted
Not inverted
-
01
Bit 1
Inverted
Not inverted
-
02
Bit 2
Inverted
Not inverted
-
03
Bit 3
Inverted
Not inverted
-
04
Bit 4
Inverted
Not inverted
-
05
Bit 5
Inverted
Not inverted
-
06
Bit 6
Inverted
Not inverted
-
07
Bit 7
Inverted
Not inverted
-
08
Bit 8
Inverted
Not inverted
-
09
Bit 9
Inverted
Not inverted
-
10
Bit 10
Inverted
Not inverted
-
11
Bit 11
Inverted
Not inverted
-
12
Bit 12
Inverted
Not inverted
-
13
Bit 13
Inverted
Not inverted
-
14
Bit 14
Inverted
Not inverted
-
15
Bit 15
Inverted
Not inverted
-
p8899[0...1]
CI: IF2 connector-binector converter signal source / Con/bin S_src
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32 / Integer16
Func. diagram:
2485, 2491
Min Max
Factory
setting
- -
0
r8909
PN device ID / PN device ID
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
- -
-
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...