SINAMICS DCP
List Manual (LH21), 05/2016
251
2 Parameters
2.2 List of parameters
Description:
Sets the signal source for the output value at analog output 0 (AO 0, X177.49/50).
Note:
AO: Analog Output
Description:
Sets the mode for signal processing at analog output 0 (AO 0, X177.49/50).
Value:
0:
Signal not influenced
1:
Signal absolute value generation
2:
Signal inverted
3:
Signal absolute value generation inverted
Note:
AO: Analog Output
Description:
Sets the time constant for smoothing the signal from analog output 0 (AO 0, X177.49/50).
Note:
AO: Analog Output
Description:
Sets the scaling for analog output 0 (AO 0, X177.49/50).
The value indicates the output value for mapping an input value of 100% at the analog output.
Note:
AO: Analog Output
Description:
Sets the offset for analog output 0 (AO 0, X177.49/50).
Note:
AO: Analog Output
Description:
Sets the signal source for the output value at analog output 1 (AO 1, X177.51/52).
Note:
AO: Analog Output
p50750
CI: CUD analog output 0 signal source / CUD AO 0 s_src
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Func. diagram:
2095
Min Max
Factory
setting
- -
0
p50751
CUD analog output 0 signal processing / CUD AO 0 sig proc
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Integer16
Func. diagram:
2095
Min Max
Factory
setting
0 3
0
p50752
CUD analog output 0 smoothing time constant / CUD AO 0 T
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
2095
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
p50753
CUD analog output 0 scaling / CUD AO 0 scal
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
2095
Min Max
Factory
setting
-200.00 [V]
200.00 [V]
10.00 [V]
p50754
CUD analog output 0 offset / CUD AO 0 offs
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
2095
Min Max
Factory
setting
-10.00 [V]
10.00 [V]
0.00 [V]
p50755
CI: CUD analog output 1 signal source / CUD AO 1 s_src
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32 / FloatingPoint32
Func. diagram:
2095
Min Max
Factory
setting
- -
0
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...