2 Parameters
2.2 List of parameters
SINAMICS DCP
146
List Manual (LH21), 05/2016
Dependency:
The simulation of a digital input is selected using p4095.
Refer to: p4095
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the setpoint for the input signals in the simulation mode of the digital inputs of Terminal Module 31 (TM31).
Dependency:
The simulation of a digital input is selected using p4095.
Refer to: p4095
Note:
This parameter is not saved when data is backed-up (p0971, p0977).
DI: Digital Input
DI/DO: Bidirectional Digital Input/Output
Description:
Sets the simulation mode for the analog inputs of Terminal Module 31 (TM31).
Value:
0:
Terminal evaluation for analog input x
1:
Simulation for analog input x
Index:
[0] = AI 0 (X521.1/X521.2, S5.0)
[1] = AI 1 (X521.3/X521.4, S5.1)
06
DI/DO 6 (X520.8)
High
Low
-
07
DI/DO 7 (X520.9)
High
Low
-
08
DI/DO 8 (X521.2)
High
Low
-
09
DI/DO 9 (X521.3)
High
Low
-
10
DI/DO 10 (X521.4)
High
Low
-
11
DI/DO 11 (X521.5)
High
Low
-
12
DI/DO 12 (X521.6)
High
Low
-
13
DI/DO 13 (X521.7)
High
Low
-
14
DI/DO 14 (X521.8)
High
Low
-
15
DI/DO 15 (X521.9)
High
Low
-
16
DI/DO 16 (X522.2)
High
Low
-
17
DI/DO 17 (X522.3)
High
Low
-
18
DI/DO 18 (X522.4)
High
Low
-
19
DI/DO 19 (X522.5)
High
Low
-
20
DI/DO 20 (X522.6)
High
Low
-
21
DI/DO 21 (X522.7)
High
Low
-
22
DI/DO 22 (X522.8)
High
Low
-
23
DI/DO 23 (X522.9)
High
Low
-
p4096
TM31 digital inputs simulation mode setpoint / TM31 DI sim setp
TM31
Can be changed:
U, T
Access level:
2
Data type:
Unsigned32
Func. diagram:
9549, 9550,
9552, 9560, 9562
Min Max
Factory
setting
-
-
0000 0000 0000 0000 bin
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DI 0 (X520.1)
High
Low
-
01
DI 1 (X520.2)
High
Low
-
02
DI 2 (X520.3)
High
Low
-
03
DI 3 (X520.4)
High
Low
-
04
DI 4 (X530.1)
High
Low
-
05
DI 5 (X530.2)
High
Low
-
06
DI 6 (X530.3)
High
Low
-
07
DI 7 (X530.4)
High
Low
-
08
DI/DO 8 (X541.2)
High
Low
-
09
DI/DO 9 (X541.3)
High
Low
-
10
DI/DO 10 (X541.4)
High
Low
-
11
DI/DO 11 (X541.5)
High
Low
-
p4097[0...1]
TM31 analog inputs simulation mode / TM31 AI sim_mode
TM31
Can be changed:
U, T
Access level:
2
Data type:
Integer16
Func. diagram:
9566, 9568
Min Max
Factory
setting
0 1
0
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...