SINAMICS DCP
List Manual (LH21), 05/2016
181
2 Parameters
2.2 List of parameters
The multiple trace is de-activated with a value = 0.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: r4841, p4844
Refer to: A02097, A02098
Notice:
A multiple trace can have a negative impact on the total system performance.
From their inherent principle of operation, flash memory cards are subject to wear as a result of write operations. As
a consequence, the lifetime of flash memory cards is reduced when using the multiple trace functionality.
Description:
Displays the currently running cycle (including deadtime) of the multiple trace.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: p4840, p4844
Description:
Sets the number of ring buffer files for the measurement results of the multiple trace.
Index:
[0] = Trace 0
[1] = Trace 1
Dependency:
Refer to: p4840, r4841
Description:
Displays the number of OA applications installed on this drive object.
Dependency:
Refer to: r4951, r4952, r4955, p4956, r4957, r4958, r4959, r4960
Note:
DO: Drive Object
OA: Open Architecture (OA application)
Description:
Displays the total length of the identifiers of the OA applications installed on this drive object.
Dependency:
Refer to: r4950, r4952, r4955, p4956, r4957, r4958, r4959, r4960
Note:
The identifier of an OA application comprises a maximum of 8 characters plus separator.
Description:
Displays the total length of the GUIDs of the OA applications installed on this drive object.
r4841[0...1]
MTrace cycle actual display / Cycle act display
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
p4844[0...1]
MTrace ring buffer files number / Ring buff file qty
CU_DCP
Can be changed:
T
Access level:
3
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
5 5
5
r4950
OA DO-specific number / OA DO qty
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed:
-
Access level:
4
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 16
-
r4951
OA DO-specific identifier total length / OA DO id tot_lgth
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed:
-
Access level:
4
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 144
-
r4952
OA DO-specific GUID total length / OA DO GUID length
CU_DCP, TM150,
TM15DI_DO, TM31
Can be changed:
-
Access level:
4
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 288
-
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...