2 Parameters
2.2 List of parameters
Description:
Sets the operating mode for "PV array flying connection".
Value:
0:
No "PV array flying connection"
1:
"PV array flying connection" on side 1
2:
"PV array flying connection" on side 2
Dependency:
Refer to: p55350
Refer to: F60058, F60500
Note:
- it is not permissible to set p55350 < 3 - and at the same time set p55110 > 0 (F60058).
- for p55110 > 0, when reaching the dynamic overvoltage limits (p55182, p55187) fault F60500 is initiated.
Description:
Display and connector output for the minimum current of the PV array.
This minimum current is necessary in order to draw a PV array into the normal voltage range.
Description:
Display and connector output for the absolute value of the currently valid current limit.
Description:
Display and connector output for the reactor current setpoint after the current/power limiting.
Description:
Display and connector output for the reactor current setpoint after the voltage limiting.
Description:
Display and connector output for the status of the setpoint limiting.
p55110
PV array flying connection operating mode / PV FlyConn op_mode
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
Integer16
Func. diagram:
6810
Min Max
Factory
setting
0 2
0
r55112
CO: PV array minimum current / PV I_min
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6810
Min Max
Factory
setting
- [%]
- [%]
- [%]
r55115
CO: Limit actual current limit / Lim I_lim actual
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6810
Min Max
Factory
setting
- [%]
- [%]
- [%]
r55120
CO: Current/power limit reactor current setpoint output / I/P_lim I_reac_set
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6810
Min Max
Factory
setting
- [%]
- [%]
- [%]
r55122
CO: Voltage limiting reactor current setpoint output / U_lim I_react_set
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6812
Min Max
Factory
setting
- [%]
- [%]
- [%]
r55125.0...15
CO/BO: Limitation status / Lim status
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
6810
Min Max
Factory
setting
- -
-
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...