2 Parameters
2.2 List of parameters
SINAMICS DCP
64
List Manual (LH21), 05/2016
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
The parameter is set to the factory setting when the protocol is reselected.
Description:
Sets the number of 16-bit words in the PZD part of the USS telegram for the field bus interface.
Dependency:
Refer to: p2030
Note:
The parameter is not influenced by setting the factory setting.
Description:
Sets the number of 16-bit words in the PKW part of the USS telegram for the field bus interface.
Value:
0:
PKW 0 words
3:
PKW 3 words
4:
PKW 4 words
127:
PKW variable
Dependency:
Refer to: p2030
Note:
The parameter is not influenced by setting the factory setting.
Description:
Displays the receive errors on the field bus interface (USS).
Index:
[0] = Number of error-free telegrams
[1] = Number of rejected telegrams
[2] = Number of framing errors
[3] = Number of overrun errors
[4] = Number of parity errors
[5] = Number of starting character errors
[6] = Number of checksum errors
[7] = Number of length errors
Description:
Sets the communication protocol for the field bus interface.
Value:
0:
No protocol
1:
USS
3:
PROFIBUS
Note:
Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
p2022
Field bus int USS PZD no. / Field bus USS PZD
CU_DCP
Can be changed:
T
Access level:
2
Data type:
Unsigned16
Func. diagram:
9310
Min Max
Factory
setting
0 16
2
p2023
Field bus int USS PKW no. / Field bus USS PKW
CU_DCP
Can be changed:
T
Access level:
2
Data type:
Integer16
Func. diagram:
9310
Min Max
Factory
setting
0 127
127
r2029[0...7]
Field bus int error statistics / Field bus error
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Func. diagram:
9310
Min Max
Factory
setting
- -
-
p2030
Field bus int protocol selection / Field bus protocol
CU_DCP
Can be changed:
T
Access level:
1
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 3
3
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...