2 Parameters
2.2 List of parameters
SINAMICS DCP
28
List Manual (LH21), 05/2016
Description:
Sets the parameter filter for commissioning a Terminal Module 150 (TM150).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
Ready
29:
Only Siemens int
30:
Parameter reset
Dependency:
Refer to: p0970
Note:
Only the following values are possible: p0010 = 0, 30
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
Description:
Sets the parameter filter for commissioning a Terminal Module 15 (TM15).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
Ready
29:
Only Siemens int
30:
Parameter reset
Dependency:
Refer to: p0970
Note:
Only the following values are possible: p0010 = 0, 30
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
Description:
Sets the parameter filter for commissioning a Terminal Module 31 (TM31).
Setting this parameter filters out the parameters that can be written into in the various commissioning steps.
For the BOP, this setting also causes the read access operations to be filtered.
Value:
0:
Ready
29:
Only Siemens int
30:
Parameter reset
Dependency:
Refer to: p0970
Note:
Only the following values are possible: p0010 = 0, 30
Procedure for "Reset parameter": Set p0010 to 30 and p0970 to 1.
Description:
Sets the password for the Basic Operator Panel (BOP).
Dependency:
Refer to: p0012, p0013
p0010
TM150 commissioning parameter filter / TM150 com par_filt
TM150
Can be changed:
C2(1), T
Access level:
1
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 30
0
p0010
TM15DI/DO commissioning the parameterizing filter / TM15D com par_filt
TM15DI_DO
Can be changed:
C2(1), T
Access level:
1
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 30
0
p0010
TM31 commissioning parameter filter / TM31 comm par_filt
TM31
Can be changed:
C2(1), T
Access level:
1
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 30
0
p0011
BOP password entry (p0013) / BOP passw ent p13
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 65535
0
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...