SINAMICS DCP
List Manual (LH21), 05/2016
177
2 Parameters
2.2 List of parameters
Description:
Sets the reference value for 100 % for referred inputs.
Dependency:
Only effective when p4810 = 99.
Description:
Sets the scaling for the integer number of the output signal for the function generator.
Dependency:
Refer to: r4805, r4817
Note:
The parameter can only be changed in the following operating states:
r4805 = 0, 4, 6
Description:
Display and connector output for the integer number of the output signal for the function generator.
Dependency:
Refer to: p4816
Note:
The value is output independent of the function generator operating mode.
Description:
Displays the output signal for the function generator.
Dependency:
Refer to: p4810
Note:
The value is displayed independently of the function generator mode.
Description:
Sets the signal source to control the function generator.
When the function generator is running, signal generation is stopped with a 0 signal from BI: p4819 and p4800 is set
to 0.
Dependency:
Refer to: p4800
Description:
Sets the signal to be generated for the function generator.
p4813
Function generator physical address reference value / FG phys addr ref
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
1.00 1000000.00
1.00
p4816
Function generator output signal integer number scaling / FG outp integ scal
CU_DCP
Can be changed:
U, T
Access level:
4
Data type:
Integer32
Func. diagram:
-
Min Max
Factory
setting
-2147483648 2147483647
0
r4817
CO: Function generator output signal integer number / FG outp integ no.
CU_DCP
Can be changed:
-
Access level:
4
Data type:
Integer32
Func. diagram:
-
Min Max
Factory
setting
- -
-
r4818
CO: Function generator output signal / FG outp_sig
CU_DCP
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
p4819
BI: Function generator control / FG control
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
Unsigned32 / Binary
Func. diagram:
-
Min Max
Factory
setting
- -
1
p4820
Function generator signal shape / FG signal shape
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
1 5
1
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...