2 Parameters
2.2 List of parameters
SINAMICS DCP
74
List Manual (LH21), 05/2016
Note:
IF1: Interface 1
Description:
Status display for the PROFIBUS interface.
Value:
0:
OFF
1:
No connection (search for baud rate)
2:
Connection OK (baud rate found)
3:
Cyclic connection with master (data exchange)
4:
Cyclic data OK
Note:
Re r2054 = 3:
In state 3 (the LED flashes green), a cyclic connection has been established to the PROFIBUS master; however, one
of the following prerequisites is missing for cyclic operation:
- No setpoints are being received as the PROFIBUS master is in the STOP condition.
Only for clock-cycle synchronous operation, the following applies:
- The drive is not in synchronism as the global control (GC) has an error.
Re r2054 = 4:
In the status 4 (LED green), the cyclic connection to the PROFIBUS master has been established and setpoints are
being received. The clock cycle synchronization is OK, the global control (GC) is error-free.
This state does not provide any statement regarding the quality of the clock cycle synchronous sign-of-life characters
on the drive objects.
Description:
Diagnostics display for the PROFIBUS interface.
Index:
[0] = Master bus address
[1] = Master input total length bytes
[2] = Master output total length bytes
Description:
Connector output to interconnect PZD (setpoints) with double word format received from the fieldbus controller.
Index:
[0] = PZD 1 + 2
[1] = PZD 2 + 3
[2] = PZD 3 + 4
[3] = PZD 4 + 5
[4] = PZD 5 + 6
[5] = PZD 6 + 7
[6] = PZD 7 + 8
[7] = PZD 8 + 9
07
Bit 7
ON
OFF
-
08
Bit 8
ON
OFF
-
09
Bit 9
ON
OFF
-
10
Bit 10
ON
OFF
-
11
Bit 11
ON
OFF
-
12
Bit 12
ON
OFF
-
13
Bit 13
ON
OFF
-
14
Bit 14
ON
OFF
-
15
Bit 15
ON
OFF
-
r2054
PROFIBUS status / PB status
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Integer16
Func. diagram:
2410
Min Max
Factory
setting
0 4
-
r2055[0...2]
PROFIBUS diagnostics standard / PB diag standard
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
2410
Min Max
Factory
setting
- -
-
r2060[0...62]
CO: IF1 PROFIdrive PZD receive double word / IF1 PZD recv DW
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
Integer32
Func. diagram:
2440, 2460
Min Max
Factory
setting
- -
-
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...