SINAMICS DCP
List Manual (LH21), 05/2016
297
2 Parameters
2.2 List of parameters
Description:
Sets the charging current for precharging using using the "pulsing up" technique.
Description:
Setting to test the contactors.
Value:
0:
No contactor test
11:
Close precharging contactor side 1
12:
Close DC contactor side 1
21:
Close precharging contactor side 2
22:
Close DC contactor side 2
Description:
Display and BICO output for the state of the contactors.
Description:
Display and connector output for the trace in the power unit.
Index:
[0] = Voltage controller P component (r54131)
[1] = Voltage controller I component (r54132)
[2] = Current setpoint (r55172)
[3] = Voltage 1 (r55501)
[4] = Voltage 2 (r55502)
[5] = Precontrol output (r55210)
[6] = Current controller output (r55201)
[7] = Current controller I component (r55202)
[8] = Current actual value (r55511)
[9] = Control angle power unit 1 (r55250)
Note:
The trace can be triggered in the following ways:
- p50831 = 1 (manual trigger)
- overcurrent (automatic trigger)
- overvoltage (automatic trigger)
It takes approximately 5 ms to record the trace.
The signals to be traced are fixed and cannot be changed.
The recorded trace is output periodically at this parameter. Between the individual repeats, there is a pause (all
signals = 0) of approximately 5 ms.
p55360
Precharging charge current / Prechrg I_charge
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6835
Min Max
Factory
setting
0.000 [%]
100.000 [%]
5.000 [%]
p55370
Contactor test / Contactor test
DCP_CTRL
Can be changed:
T
Access level:
4
Data type:
Integer16
Func. diagram:
6835
Min Max
Factory
setting
0 22
0
r55375.0...3
CO/BO: State of the contactors / Contactor state
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
6835
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Precharging contactor side 1
On
Off
6835
01
DC contactor side 1
On
Off
6835
02
Precharging contactor side 2
On
Off
6835
03
DC contactor side 2
On
Off
6835
r55399[0...9]
CO: Trace power unit / Trace PU
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
8054
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...