2 Parameters
2.2 List of parameters
SINAMICS DCP
158
List Manual (LH21), 05/2016
Description:
Setting to activate/deactivate the filter to smooth the temperature signal for the Terminal Module 150 (TM150).
The smoothing is realized with a 1st order lowpass filter
The effective smoothing time constant depends on the number of channels that are simultaneously active and is
displayed in r4120.
Value:
0:
Filter deactivated
1:
Filter activated
Index:
[0] = Temperature channel 0
[1] = Temperature channel 1
[2] = Temperature channel 2
[3] = Temperature channel 3
[4] = Temperature channel 4
[5] = Temperature channel 5
[6] = Temperature channel 6
[7] = Temperature channel 7
[8] = Temperature channel 8
[9] = Temperature channel 9
[10] = Temperature channel 10
[11] = Temperature channel 11
Dependency:
Refer to: r4120
Description:
Displays the smoothing time constant for the temperature filter for Terminal Module 150 (TM150).
Dependency:
Refer to: r4105, p4111, r4112, r4113
Note:
The time constant lies in the range from 80 to 1000 ms and depends on the number of channels that are
simultaneously active.
Description:
Sets the rated line frequency for the filter to skip the line frequency for Terminal Module 150 (TM150).
Value:
0:
50 Hz
1:
60 Hz
Description:
Trace functionality for OEM encoder manufacturers.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
p4119[0...11]
TM150 activate/deactivate smoothing / TM150 smooth act
TM150
Can be changed:
T
Access level:
1
Data type:
Integer16
Func. diagram:
9626, 9627
Min Max
Factory
setting
0 1
0
r4120
TM150 temperature filter time constant / TM150 temp_filt T
TM150
Can be changed:
-
Access level:
1
Data type:
Unsigned16
Func. diagram:
9626, 9627
Min Max
Factory
setting
- [ms]
- [ms]
- [ms]
p4121
TM150 filter rated line frequency / TM150 filt f_line
TM150
Can be changed:
T
Access level:
1
Data type:
Integer16
Func. diagram:
9626, 9627
Min Max
Factory
setting
0 1
0
p4641[0...2]
OEM encoder diagnostic signal selection / OEM enc diag sel
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 65535
0
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...