Description:
Displays the calculated DRIVE-CLiQ bandwidth load based on the existing target topology.
The values are not made available until the RUNUP READY (800) state is adopted (see p3988).
Index 0 ... 7 corresponds to DRIVE-CLiQ socket X100 ... X107.
Dependency:
Refer to: F01340
Description:
Displays the calculated DRIVE-CLiQ DPRAM load based on the existing target topology.
The values are not made available until the RUNUP READY (800) state is adopted (see p3988).
Index 0 ... 7 corresponds to DRIVE-CLiQ socket X100 ... X107.
Dependency:
Refer to: F01340
Description:
The meaning of the parameter differs for reading and writing.
Read:
- Returns the number of memory areas monitored.
Write:
- Memory usage of a drive object: Enter drive object number
- Memory usage of the complete system: Enter value 65535
Description:
Displays the memory usage for each drive object as actual value.
Index:
[0] = Fast Memory 1
[1] = Fast Memory 2
[2] = Fast Memory 3
[3] = Fast Memory 4
[4] = Heap
Description:
Displays the memory usage for each drive object as reference value.
r9987[0...7]
DRIVE-CLiQ bandwidth load / DQ bandw load
CU_DCP
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
r9988[0...7]
DRIVE-CLiQ DPRAM load / DQ DPRAM load
CU_DCP
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
p9990
DO memory usage actual value determination selection / Mem_use ActVal sel
CU_DCP
Can be changed:
U, T
Access level:
4
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 65535
0
r9991[0...4]
Memory usage drive object actual value / Mem_use DO ActVal
CU_DCP
Can be changed:
-
Access level:
4
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
r9992[0...4]
Memory usage drive object reference value / Mem_use DO ref val
CU_DCP
Can be changed:
-
Access level:
4
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...