SINAMICS DCP
List Manual (LH21), 05/2016
169
2 Parameters
2.2 List of parameters
Description:
Displays the trace buffer (record buffer) for trace 1 and signal 5.
Dependency:
Refer to: r4740, p4795
Description:
Displays the trace buffer (record buffer) for trace 1 and signal 6.
Dependency:
Refer to: r4740, p4795
Description:
Displays the trace buffer (record buffer) for trace 1 and signal 7.
Dependency:
Refer to: r4740, p4795
Description:
Displays the trace buffer (record buffer) for trace 0 and signal 0 as integer number.
Note:
For signals, data type I32 or U32, the trace buffer is assigned as follows:
r4760[0] = value 0
r4760[1] = value 1
...
r4760[8191] = value 8191
For signals, data type I16 or U16, the trace buffer is assigned as follows:
r4760[0] = value 1 (bit 31 ... 16) and value 0 (bit 15 ... 0)
r4760[1] = value 3 (bit 31 ... 16) and value 2 (bit 15 ... 0)
...
r4760[8191] = value 16383 (bit 31 ... 16) and value 16382 (bit 15 ... 0)
For signals, data type I8 or U8, the trace buffer is assigned as follows:
r4760[0] = value 3 (bit 31 ... 24) value 2 (bit 23 ... 16) value 1 (bit 15 ... 8) value 0 (bit 7 ... 0)
r4760[1] = value 7 (bit 31 ... 24) value 6 (bit 23 ... 16) value 5 (bit 15 ... 8) value 4 (bit 7 ... 0)
...
r4760[8191] = value 32767 (bit 31 ... 24) value 32766 (bit 23 ... 16) value 32765 (bit 15 ... 8) value 32764 (bit 7 ... 0)
Description:
Displays the trace buffer (record buffer) for trace 0 and signal 1.
r4755[0...16383] Trace 1 trace buffer signal 5 floating point / Trace 1 tr sig 5
CU_DCP
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- -
-
r4756[0...16383] Trace 1 trace buffer signal 6 floating point / Trace 1 tr sig 6
CU_DCP
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- -
-
r4757[0...16383] Trace 1 trace buffer signal 7 floating point / Trace 1 tr sig 7
CU_DCP
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- -
-
r4760[0...16383] Trace 0 trace buffer signal 0 / Trace 0 tr sig 0
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
r4761[0...16383] Trace 0 trace buffer signal 1 / Trace 0 tr sig 1
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...