SINAMICS DCP
List Manual (LH21), 05/2016
109
2 Parameters
2.2 List of parameters
Description:
Displays the system runtime in days when the fault occurred.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2114, r2133, r2136, r3115, r3120, r3122
Notice:
The time comprises r2130 (days) and r0948 (milliseconds).
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description:
Displays the code of the oldest active fault.
Dependency:
Refer to: r3131, r3132
Note:
0: No fault present.
Description:
Displays the code of the last alarm that occurred.
Note:
0: No alarm present.
Description:
Displays additional information about the fault that occurred for float values.
Dependency:
Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2136, r3115
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description:
Displays additional information about the active alarm for float values.
Dependency:
Refer to: r2110, r2122, r2123, r2124, r2125, r2145, r2146, r3121, r3123
Note:
The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description:
Display and BICO output for the second status word of faults and alarms.
r2130[0...63]
Fault time received in days / t_fault recv days
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
8060
Min Max
Factory
setting
- -
-
r2131
CO: Actual fault code / Act fault code
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
8060
Min Max
Factory
setting
- -
-
r2132
CO: Actual alarm code / Actual alarm code
All objects
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
8065
Min Max
Factory
setting
- -
-
r2133[0...63]
Fault value for float values / Fault val float
All objects
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
8060
Min Max
Factory
setting
- -
-
r2134[0...63]
Alarm value for float values / Alarm value float
All objects
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
8065
Min Max
Factory
setting
- -
-
r2135.0...2
CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
CU_DCP
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
2548
Min Max
Factory
setting
- -
-
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...