2 Parameters
2.2 List of parameters
Description:
Displays the directory and name of the file whose status as shipped from the factory was identified as impermissible.
Dependency:
Refer to: r9926
Refer to: A01016
Note:
The directory and name of the file is displayed in the ASCII code.
Description:
Displays the status when the firmware is checked when the system is booted.
0: Firmware not yet checked.
1: Check running.
2: Check successfully completed.
3: Check indicates an error.
Dependency:
Refer to: r9925
Refer to: A01016
Description:
Displays the measured system utilization.
The higher the value displayed, the higher the system utilization.
Index:
[0] = Computing time utilization (min)
[1] = Computing time utilization (averaged)
[2] = Computing time utilization (max)
[3] = Largest total utilization (min)
[4] = Largest total utilization (averaged)
[5] = Largest total utilization (max)
[6] = Reserved
[7] = Reserved
Dependency:
Refer to: r9976, r9979, r9980, r9981
Refer to: F01054, F01205
Note:
Re index 3 ... 5:
The total utilizations are determined using all sampling times used. The largest total utilizations are mapped here.
The sampling time with the largest total utilization is displayed in r9979.
Total utilization:
Computing time load of sampling time involved including load from higher-priority sampling times (interrupts).
Description:
Displays the system utilization.
If the utilization is greater than 100%, fault F01054 is output.
r9925[0...99]
Firmware file incorrect / FW file incorr
CU_DCP
Can be changed:
-
Access level:
2
Data type:
Unsigned8
Func. diagram:
-
Min Max
Factory
setting
- -
-
r9926
Firmware check status / FW check status
CU_DCP
Can be changed:
-
Access level:
2
Data type:
Unsigned8
Func. diagram:
-
Min Max
Factory
setting
- -
-
r9975[0...7]
System utilization measured / Sys util meas
CU_DCP
Can be changed:
-
Access level:
4
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
r9976[0...7]
System utilization / Sys util
CU_DCP
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...