2 Parameters
2.2 List of parameters
SINAMICS DCP
178
List Manual (LH21), 05/2016
Value:
1:
Square-wave
2:
Staircase
3:
Delta
4:
Binary noise - PRBS (Pseudo Random Binary Signal)
5:
Sine-wave
Description:
Sets the period of the signal to be generated for the function generator.
Dependency:
Ineffective when p4820 = 4 (PRBS).
Description:
Sets the pulse width for the signal to be generated for the function generator.
Dependency:
Only effective when p4820 = 1 (square-wave).
Description:
Sets the bandwidth for the signal to be generated for the function generator.
Dependency:
Only effective when p4820 = 4 (PRBS).
Refer to: p4830
Refer to: A02041
Description:
Sets the amplitude for the signal to be generated for the function generator.
Dependency:
Units are dependent on p4810.
If p4810 = 1, 2, 4: The amplitude is referred to p2002 (reference current).
If p4810 = 3, 5: The amplitude is referred to p2000 (reference speed).
Description:
Sets the second amplitude for the signal to be generated for the function generator.
Dependency:
Only effective for p4820 = 2 (staircase).
Units are dependent on p4810.
If p4810 = 1, 2, 4: The amplitude is referred to p2002 (reference current).
If p4810 = 3, 5: The amplitude is referred to p2000 (reference speed).
p4821
Function generator period / FG period duration
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
0.00 [ms]
60000.00 [ms]
1000.00 [ms]
p4822
Function generator pulse width / FG pulse width
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
0.00 [ms]
60000.00 [ms]
500.00 [ms]
p4823
Function generator bandwidth / FG bandwidth
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
0.0025 [Hz]
16000.0000 [Hz]
4000.0000 [Hz]
p4824
Function generator amplitude / FG amplitude
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
-1600.00 [%]
1600.00 [%]
5.00 [%]
p4825
Function generator 2nd amplitude / FG 2nd amplitude
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
-
Min Max
Factory
setting
-1600.00 [%]
1600.00 [%]
7.00 [%]
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...