SINAMICS DCP
List Manual (LH21), 05/2016
47
2 Parameters
2.2 List of parameters
Note:
Re bit 02:
A data set changeover is delayed by the time required for the internal parameter calculation.
Description:
Displays the command data set (CDS) selected via the binector input.
Dependency:
Refer to: r0050, p0810
Note:
Command data sets are selected via binector input p0810.
The currently effective command data set is displayed in r0050.
Description:
Displays the drive data set (DDS) selected via the binector input.
Dependency:
Refer to: r0051, p0820, p0821
Note:
Drive data sets are selected via binector input p0820 and following.
The currently effective drive data set is displayed in r0051.
Description:
Sets the signal source for the command "ON/OFF (OFF1)".
For the PROFIdrive profile, this command corresponds to control word 1 bit 0 (STW1.0).
Recommendation:
When the setting for this binector input is changed, the motor can only be switched on by means of an appropriate
signal change of the source.
Caution:
When "master control from PC" is activated, this binector input is ineffective.
Notice:
For binector input p0840 = 0 signal, the motor can be moved, jogging using binector input p1055 or p1056.
The command "ON/OFF (OFF1)" can be issued using binector input p0840 or p1055/p1056.
For binector input p0840 = 0 signal, the switch-on inhibit is acknowledged.
Only the signal source that originally powered up can also power down again.
The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note:
For drives with closed-loop speed control (p50084 = 1), the following applies:
- BI: p0840 = 0 signal: OFF1 (braking with the ramp-function generator, then pulse suppression and switch-on inhibit)
For drives with closed-loop torque control (p50084 = 2), the following applies:
- BI: p0840 = 0 signal: immediate pulse suppression
For drives with closed-loop speed/torque control, the following applies:
- BI: p0840 = 0/1 signal: ON (pulses can be enabled)
r0836.0
CO/BO: Command Data Set CDS selected / CDS selected
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
Unsigned8
Func. diagram:
8560
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
CDS select. bit 0
ON
OFF
-
r0837.0...1
CO/BO: Drive Data Set DDS selected / DDS selected
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned8
Func. diagram:
8565
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DDS select. bit 0
ON
OFF
-
01
DDS select. bit 1
ON
OFF
-
p0840[0...n]
BI: ON / OFF (OFF1) / ON / OFF (OFF1)
DCP_CTRL
Can be changed:
T
Access level:
3
Data type:
Unsigned32 / Binary
Func. diagram:
2460, 2580
Min Max
Factory
setting
- -
[0]
2090.0
[1] 1
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...