SINAMICS DCP
List Manual (LH21), 05/2016
269
2 Parameters
2.2 List of parameters
Dependency:
For bit 08 ... 15:
The terminal must be set as an input (p50789[0...3] = 0).
Note:
DI: Digital Input
DI/DO: bidirectional digital input/digital output
Description:
Display and connector output for the CUD's digital outputs.
Dependency:
For bits 04 ... 07:
The terminal must be set as an output (p50789[0...3] = 1).
Note:
DO: Digital Output
DI/DO: bidirectional digital input/digital output
Description:
Display and connector output for the overload monitoring of the digital outputs.
Dependency:
For bits 04 ... 07:
The terminal must be set as an output (p50789[0...3] = 1).
Note:
DO: Digital Output
DI/DO: bidirectional digital input/digital output
06
DI 3 (X177.14)
High
Low
2050
07
DI 3 inverted (X177.14)
High
Low
2050
08
DI/DO 4 (X177.15)
High
Low
2060
09
DI/DO 4 inverted (X177.15)
High
Low
2060
10
DI/DO 5 (X177.16)
High
Low
2060
11
DI/DO 5 inverted (X177.16)
High
Low
2060
12
DI/DO 6 (X177.17)
High
Low
2065
13
DI/DO 6 inverted (X177.17)
High
Low
2065
14
DI/DO 7 (X177.18)
High
Low
2065
15
DI/DO 7 inverted (X177.18)
High
Low
2065
r53020.0...7
CO/BO: CUD digital outputs status / CUD DO status
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
2055, 2060,
2065
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DO 0 (X177.19)
High
Low
2055
01
DO 1 (X177.20)
High
Low
2055
02
DO 2 (X177.21)
High
Low
2055
03
DO 3 (X177.22)
High
Low
2055
04
DI/DO 4 (X177.15)
High
Low
2060
05
DI/DO 5 (X177.16)
High
Low
2060
06
DI/DO 6 (X177.17)
High
Low
2065
07
DI/DO 7 (X177.18)
High
Low
2065
r53021.0...7
CO/BO: CUD digital outputs overload monitoring / CUD DO overl_monit
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
Unsigned16
Func. diagram:
2055, 2060,
2065
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
DO 0 (X177.19) overload present
Yes
No
2055
01
DO 1 (X177.20) overload present
Yes
No
2055
02
DO 2 (X177.21) overload present
Yes
No
2055
03
DO 3 (X177.22) overload present
Yes
No
2055
04
DI/DO 4 (X177.15) overload present
Yes
No
2060
05
DI/DO 5 (X177.16) overload present
Yes
No
2060
06
DI/DO 6 (X177.17) overload present
Yes
No
2065
07
DI/DO 7 (X177.18) overload present
Yes
No
2065
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...