2 Parameters
2.2 List of parameters
SINAMICS DCP
294
List Manual (LH21), 05/2016
Description:
Sets the integrating time for the differential current controller
Description:
Sets the limiting for the differential current controller.
Description:
Sets the operating mode for the closed-loop control.
Value:
0:
Closed-loop controlled operation
1:
Directly controlled PWM
Note:
Setting p55270 = 1 is only for internal Siemens testing.
Description:
Sets the positive limiting for the control angle.
In conjunction with p55306, it is possible to restrict the operating range of the SINAMICS DCP.
Dependency:
Refer to: p55306
Note:
Examples:
Control angle limited to:
0 ... +200 %: only positive current possible
-200 ... 0 %: only negative current possible
-100 ... +100 %: only step-down possible
Description:
Sets the negative limiting for the control angle.
In conjunction with p55305, it is possible to restrict the operating range of the SINAMICS DCP.
Dependency:
Refer to: p55305
Note:
Examples:
Control angle limited to:
0 ... +200 %: only positive current possible
-200 ... 0 %: only negative current possible
-100 ... +100 %: only step-down possible
p55260
Differential current controller integrating time / I_diff_ctrl t_int
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6825
Min Max
Factory
setting
0.001 [s]
5000.000 [s]
100.000 [s]
p55262
Differential current controller limiting / I_diff_ctrl limit
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6825
Min Max
Factory
setting
0.000 [%]
50.000 [%]
10.000 [%]
p55270
Closed-loop control mode / Cl-loop ctrl_mode
DCP_CTRL
Can be changed:
T
Access level:
2
Data type:
Integer16
Func. diagram:
6825
Min Max
Factory
setting
0 1
0
p55305
Modulator control angle limiting positive / Mod ctrAng lim pos
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6825
Min Max
Factory
setting
0.00 [%]
200.00 [%]
200.00 [%]
p55306
Modulator control angle limiting negative / Mod ctrAng lim neg
DCP_CTRL
Can be changed:
U, T
Access level:
2
Data type:
FloatingPoint32
Func. diagram:
6825
Min Max
Factory
setting
-200.00 [%]
0.00 [%]
-200.00 [%]
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...