2 Parameters
2.2 List of parameters
SINAMICS DCP
288
List Manual (LH21), 05/2016
Description:
Sets the lower threshold value for the undervoltage on side 1.
The reactor current is reduced to zero from this value.
Description:
Sets the upper threshold value for the undervoltage on side 1.
The reactor current is reduced from this value.
Description:
Sets the lower threshold value for the overvoltage on side 1.
The reactor current is reduced from this value.
Description:
Sets the upper threshold value for the overvoltage on side 1.
The reactor current is reduced to zero from this value.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Positive current limiting active
Yes
No
6810
01
Negative current limiting active
Yes
No
6810
02
Voltage in the undervoltage range
Yes
No
6810
03
Voltage in the normal voltage range below
rated voltage
Yes
No
6810
04
Voltage in the normal voltage range above
rated voltage
Yes
No
6810
05
Voltage in the overvoltage range
Yes
No
6810
06
Voltage in illegal range
Yes
No
6810
07
PV flying connection active
Yes
No
6810
08
Lower voltage limit reached on side 1
Yes
No
6812
09
Upper voltage limit reached on side 1
Yes
No
6812
10
Upper voltage limit reached on side 2
Yes
No
6812
11
Lower voltage limit reached on side 2
Yes
No
6812
12
Dynamic voltage limit reached on side 1
Yes
No
6817
13
Dynamic voltage limit reached on side 2
Yes
No
6817
14
PWM limited reached
Yes
No
6825
15
Main current controller has reached its limit
Yes
No
6820
p55130
Limiting side 1 undervoltage lower / Lim S1 U_under low
DCP_CTRL
Can be changed:
U, T
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
6812
Min Max
Factory
setting
0 [V]
1500 [V]
50 [V]
p55131
Limiting side 1 undervoltage upper / Lim S1 U_under up
DCP_CTRL
Can be changed:
U, T
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
6812
Min Max
Factory
setting
0 [V]
1500 [V]
100 [V]
p55132
Limiting side 1 overvoltage lower / Lim S1 U_over low
DCP_CTRL
Can be changed:
U, T
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
6812
Min Max
Factory
setting
0 [V]
1500 [V]
800 [V]
p55133
Limiting side 1 overvoltage upper / Lim S1 U_over up
DCP_CTRL
Can be changed:
U, T
Access level:
1
Data type:
FloatingPoint32
Func. diagram:
6812
Min Max
Factory
setting
0 [V]
1500 [V]
1000 [V]
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...