SINAMICS DCP
List Manual (LH21), 05/2016
263
2 Parameters
2.2 List of parameters
Note:
The counters are reset to 0 at POWER ON.
The counters restart at 0 after reaching a value of 65535 (overflow).
Description:
Connector output with constant fixed value value 0 %.
Description:
Connector output with constant fixed value value 100 %.
Description:
Connector output with constant fixed value value 200 %.
Description:
Connector output with constant fixed value value -100 %.
Description:
Connector output with constant fixed value value -200 %.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Abort acknowledge flag
1
0
9350
01
Write denied flag
1
0
9350
02
Wake-up flag
1
0
9350
03
Received msg lost flag
1
0
9350
04
Bus-off condition flag
1
0
9350
05
Error passive mode flag
1
0
9350
06
Warning level flag
1
0
9350
07
Form error flag
1
0
9350
08
Bit error flag
1
0
9350
09
Stuck at dominant bit
1
0
9350
10
CRC error
1
0
9350
11
Stuff bit error
1
0
9350
12
ACK error
1
0
9350
13
Bus-off status
1
0
9350
14
Error passive state
1
0
9350
15
Warning status
1
0
9350
r52000
CO: Fixed value 0 % / Fix val 0%
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
3100
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52001
CO: Fixed value 100 % / Fix val 100 %
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
3100
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52002
CO: Fixed value 200 % / Fix val 200 %
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
3100
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52003
CO: Fixed value -100 % / Fix val -100 %
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
3100
Min Max
Factory
setting
- [%]
- [%]
- [%]
r52004
CO: Fixed value -200 % / Fix val -200 %
DCP_CTRL
Can be changed:
-
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
3100
Min Max
Factory
setting
- [%]
- [%]
- [%]
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...