2 Parameters
2.2 List of parameters
Description:
The application-specific view of an existing drive object is entered into each index.
The parameter cannot be changed.
Dependency:
Refer to: p0107, r0107
Note:
The application-specific views are defined in files on the memory card with the following structure:
PDxxxyyy.ACX
xxx: Application-specific view (p0103)
yyy: Type of drive object (p0107)
Example:
PD052017.ACX
--> "017" stands for the drive object of type DC_CTRL
--> "052" is the number of the view for this drive object
Description:
Displays the application-specific view of the individual drive object.
Dependency:
Refer to: p0107, r0107
Description:
Setting to activate/de-activate a drive object.
Value:
0:
De-activate drive object
1:
Activate drive object
Dependency:
Refer to: r0106
Notice:
The following applies when activating:
If components are inserted for the first time and the appropriate drive object is activated, then the drive system is
automatically booted. To do this, the pulses of all of the drive objects must be suppressed.
Description:
Setting to activate/de-activate a drive object.
Value:
0:
De-activate drive object
1:
Activate drive object
2:
Drive object de-activate and not present
Recommendation:
After inserting all of the components of a drive object, before activating, first wait for Alarm A01316.
Dependency:
Refer to: r0106
Refer to: A01316
Notice:
The following applies when activating:
If components are inserted for the first time and the appropriate drive object is activated, then the drive system is
automatically booted. To do this, the pulses of all of the drive objects must be suppressed.
p0103[0...n]
Application-specific view / Appl_spec view
CU_DCP
Can be changed:
C1(2)
Access level:
2
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 999
0
r0103
Application-specific view / Appl_spec view
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
-
Min Max
Factory
setting
0 65535
-
p0105
Activate/de-activate drive object / DO act/deact
CU_DCP
Can be changed:
U, T
Access level:
2
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 1
1
p0105
Activate/de-activate drive object / DO act/deact
DCP_CTRL
Can be changed:
T
Access level:
2
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 2
1
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...