2 Parameters
2.2 List of parameters
SINAMICS DCP
252
List Manual (LH21), 05/2016
Description:
Sets the mode for signal processing at analog output 1 (AO 1, X177.51/52).
Value:
0:
Signal not influenced
1:
Signal absolute value generation
2:
Signal inverted
3:
Signal absolute value generation inverted
Note:
AO: Analog Output
Description:
Sets the time constant for smoothing the signal from analog output 1 (AO 1, X177.51/52).
Note:
AO: Analog Output
Description:
Sets the scaling for analog output 1 (AO 1, X177.51/52).
The value indicates the output value for mapping an input value of 100% at the analog output.
Note:
AO: Analog Output
Description:
Sets the offset for analog output 1 (AO 1, X177.51/52).
Note:
AO: Analog Output
Description:
Sets the delay time for digital input 0 (DI 0, X177.11) on the CUD.
Dependency:
Refer to: r53010
Note:
DI: Digital Input
Description:
Sets the delay time for digital input 1 (DI 1, X177.12) on the CUD.
p50756
CUD analog output 1 signal processing / CUD AO 1 sig proc
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
Integer16
Func. diagram:
2095
Min Max
Factory
setting
0 3
0
p50757
CUD analog output 1 smoothing time constant / CUD AO 1 T
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
2095
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
p50758
CUD analog output 1 scaling / CUD AO 1 scal
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
2095
Min Max
Factory
setting
-200.00 [V]
200.00 [V]
10.00 [V]
p50759
CUD analog output 1 offset / CUD AO 1 offs
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
2095
Min Max
Factory
setting
-10.00 [V]
10.00 [V]
0.00 [V]
p50765
CUD digital input 0 delay time / CUD DI 0 t_del
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
2050
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
p50766
CUD digital input 1 delay time / CUD DI 1 t_del
DCP_CTRL
Can be changed:
U, T
Access level:
3
Data type:
FloatingPoint32
Func. diagram:
2050
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...