2 Parameters
2.2 List of parameters
Description:
Displays the instant in time for fulfilling the trigger condition for trace recorder 0.
The time comprises milliseconds (index 0) and days (index 1).
Index:
[0] = Milliseconds
[1] = Days
Dependency:
Refer to: r2114, r3102, r4719
Notice:
The accuracy of the trigger instant depends on the accuracy of the underlying basis time.
For clarification:
The trigger instant is calculated with a µs accuracy. If the underlying basis time is only available with ms accuracy,
then as a result of rounding effects, an inaccuracy of 1 ms can occur.
When referred to r4719, the trigger instant can therefore deviate somewhat.
Note:
If the time calculation of the drive can be synchronized with a higher-level control, then this time can be taken from
the actual UTC time (r3102 ). Otherwise, the time is based on the system runtime (r2114).
Description:
Displays the instant in time for fulfilling the trigger condition for trace recorder 1.
The time comprises milliseconds (index 0) and days (index 1).
Index:
[0] = Milliseconds
[1] = Days
Dependency:
Refer to: r2114, r3102, r4719
Notice:
The accuracy of the trigger instant depends on the accuracy of the underlying basis time.
For clarification:
The trigger instant is calculated with a µs accuracy. If the underlying basis time is only available with ms accuracy,
then as a result of rounding effects, an inaccuracy of 1 ms can occur.
When referred to r4719, the trigger instant can therefore deviate somewhat.
Note:
If the time calculation of the drive can be synchronized with a higher-level control, then this time can be taken from
the actual UTC time (r3102 ). Otherwise, the time is based on the system runtime (r2114).
Description:
Displays the free memory for the trace in bytes.
Dependency:
Refer to: r4708
Description:
The function generator is started with p4800 = 1.
The signal is only generated for a 1 signal of binector input p4819.
r4797[0...1]
Trace 0 trigger instant / Trace 0 t_trigger
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
r4798[0...1]
Trace 1 trigger instant / Trace 1 t_trigger
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
r4799
Trace memory location free / Trace mem free
CU_DCP
Can be changed:
-
Access level:
3
Data type:
Unsigned32
Func. diagram:
-
Min Max
Factory
setting
- -
-
p4800
Function generator control / FG control
CU_DCP
Can be changed:
U, T
Access level:
3
Data type:
Integer16
Func. diagram:
-
Min Max
Factory
setting
0 3
0
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...