
2 Parameters
2.2 List of parameters
SINAMICS DCP
262
List Manual (LH21), 05/2016
Description:
Sets the signal source to initiate fault F60014 - "Telegram monitoring time expired".
The fault is triggered for a 1 signal.
Description:
Displays the diagnostics information for the parallel interface.
Index:
[0] = Telegrams transmitted without errors
[1] = Telegrams received without errors
[2] = Transmission error
[3] = Receive error
[4] = Timeouts
Note:
The counters are reset to 0 at POWER ON.
The counters restart at 0 after reaching a value of 65535 (overflow).
Description:
Displays the activities of the individual devices connected to the parallel interface.
Note:
The counters are reset to 0 at POWER ON.
The counters restart at 0 after reaching a value of 65535 (overflow).
Description:
Displays the CAN diagnostic information for the parallel interface.
p51808
BI: Parallel interface signal source for F60014 / P_IF F60014 s_src
DCP_CTRL
Can be changed:
T
Access level:
2
Data type:
Unsigned32 / Binary
Func. diagram:
9350
Min Max
Factory
setting
- -
53310.0
r51809[0...4]
Parallel interface diagnostics information / Par_IF diag info
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
9350
Min Max
Factory
setting
- -
-
r51810
Parallel interface activity display / Par_IF act disp
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
9350
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Station 1 transmitting data
Yes
No
9350
01
Station 2 transmitting data
Yes
No
9350
02
Station 3 transmitting data
Yes
No
9350
03
Station 4 transmitting data
Yes
No
9350
04
Station 5 transmitting data
Yes
No
9350
05
Station 6 transmitting data
Yes
No
9350
06
Station 7 transmitting data
Yes
No
9350
07
Station 8 transmitting data
Yes
No
9350
08
Station 9 transmitting data
Yes
No
9350
09
Station 10 transmitting data
Yes
No
9350
10
Station 11 transmitting data
Yes
No
9350
11
Station 12 transmitting data
Yes
No
9350
12
Station 13 transmitting data
Yes
No
9350
13
Station 14 transmitting data
Yes
No
9350
14
Station 15 transmitting data
Yes
No
9350
15
Station 16 transmitting data
Yes
No
9350
r51811
Parallel interface CAN diagnostics information / Par_IF CAN diag
DCP_CTRL
Can be changed:
-
Access level:
2
Data type:
Unsigned16
Func. diagram:
9350
Min Max
Factory
setting
- -
-
Содержание sinamics dcp
Страница 1: ...s SINAMICS drives SINAMICS DCP DC DC Power Converter List Manual 05 2016 Edition Siemens Parts ...
Страница 2: ......
Страница 6: ...Preface SINAMICS DCP 6 List Manual LH21 05 2016 ...
Страница 8: ...Table of contents SINAMICS DCP 8 List Manual LH21 05 2016 ...
Страница 12: ...1 Fundamental safety instructions 1 2 Industrial security SINAMICS DCP 12 List Manual LH21 05 2016 ...
Страница 380: ...3 Function diagrams 3 14 Basic Operator Panel 20 BOP20 SINAMICS DCP 380 List Manual LH21 05 2016 ...
Страница 510: ...A Appendix A 2 List of abbreviations SINAMICS DCP 510 List Manual LH21 05 2016 ...
Страница 516: ...Index SINAMICS DCP 516 List Manual LH21 05 2016 ...
Страница 517: ...Siemens Parts ...