Command Reference
R&S
®
ZNB/ZNBT
831
User Manual 1173.9163.02 ─ 55
CALCulate:FMODel:ISD<Ph_pt>:RUN[:STATe]
<Boolean>
For a fixture modeling with the ISD tool, this command allows to specify the ports to
which the deembedding files shall be assigned after the tool has run.
Suffix:
<Ph_pt>
.
Physical port number for single-ended deembedding, logical port
number for balanced deembedding.
Parameters:
<Boolean>
1 (ON) if a deembedding file shall be assinged to port <Pt>, 0
(OFF) otherwise
Example:
See
Chapter 9.2.8, "Fixture Modeling"
Manual operation:
See
CALCulate:FMODel:ISD<Ph_pt>:SCALe:ATTenuation
<AttenLeadInScaling>
Scales the test coupon’s attenuation (dB).
Sets/gets the
atten_scale 1
batch mode parameter of the ISD tool
Suffix:
<Ph_pt>
.
This suffix is ignored.
Parameters:
<AttenLeadInScaling>
Manual operation:
See
CALCulate:FMODel:ISD<Ph_pt>:SCALe:FREQuency
<MaxFrequency>
Defines the maximum frequency to deembed.
Corresponds to the
max_frequency
batch mode parameter of the ISD tool.
Suffix:
<Ph_pt>
.
This suffix is ignored.
Parameters:
<MaxFrequency>
Default unit: Hz
Manual operation:
See
CALCulate:FMODel:ISD<Ph_pt>:SCALe:FTIMe
<FltLeadInScalingTime>
Overrides the lead-in’s flight time in case the through-trace test coupon is a bit too
short or too long.
Sets/gets the
atten_scale 1
batch mode parameter of the ISD tool.
Suffix:
<Ph_pt>
.
This suffix is ignored.
SCPI Command Reference