Command Reference
R&S
®
ZNB/ZNBT
795
User Manual 1173.9163.02 ─ 55
CALCulate<Chn>:EYE:MASK:SHAPe:TOP:VERTical
........................................................ 810
CALCulate<Chn>:EYE:MASK:SHAPe:POLYgon:TYPE
...................................................... 811
CALCulate<Chn>:EYE:MASK:SHAPe:POLYgon:HORizontal
.............................................. 811
CALCulate<Chn>:EYE:MASK:SHAPe:POLYgon:VERTical
................................................. 812
.............................................................................. 812
............................................................................... 812
CALCulate<Chn>:EYE:MASK:VIOLation:RATE
.................................................................813
CALCulate<Chn>:EYE:MASK:VIOLation:TOLerance
......................................................... 813
CALCulate<Chn>:EYE:MEASurement:DATA?
...................................................................813
CALCulate<Chn>:EYE:MEASurement:STATe
................................................................... 815
CALCulate<Chn>:EYE:MEASurement:TTIMe:THReshold
.................................................. 815
.................................................................................815
CALCulate<Chn>:EYE:NOISe:STATe
...............................................................................816
......................................................................................... 816
CALCulate<Chn>:EYE:STIMulus:ENCoder
.......................................................................816
CALCulate<Chn>:EYE:STIMulus:LOWPass
..................................................................... 817
CALCulate<Chn>:EYE:STIMulus:SCRambler
................................................................... 817
.......................................................................................... 817
CALCulate<Chn>:EYE:DUT:MODE
<DUTMode>
Allows to (temporarily) switch between the measured DUT and an ideal one (with flat
frequency response) in the related eye diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<DUTMode>
IDEal | MEASured
Options:
R&S
ZNB/ZNBT-K20
Manual operation:
See
CALCulate<Chn>:EYE:EMPHasis:CURSor:POST<1|2>
<Weight>
Sets the weights of the post-cursor taps for the pre-emphasis FIR filter in the calcula-
tion chain of the related eye diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Emphasis in the generator simulation for eye diagram measurements is enabled using
CALCulate<Chn>:EYE:EMPHasis:STATe
.
Suffix:
<Chn>
.
Channel number used to identify the active trace
<1|2>
1|2
1 for the "Post 1" filter tap, 2 for the "Post 2" filter tap.
SCPI Command Reference