Appendices C Table of Parameters
C - 6
High-function General-purpose Inverter RX2 Series User’s Manual
Monitors Related to the Program Function EzSQ
Code
Name
Data range
db-01
Program download monitor
00 (Without a program)/01 (With a program)
db-02
Program number monitor
0000 to 9999
db-03
Program counter (Task-1)
1 to 1024
db-04
Program counter (Task-2)
1 to 1024
db-05
Program counter (Task-3)
1 to 1024
db-06
Program counter (Task-4)
1 to 1024
db-07
Program counter (Task-5)
1 to 1024
db-08
User monitor 0
-2147483647 to 2147483647
db-10
User monitor 1
-2147483647 to 2147483647
db-12
User monitor 2
-2147483647 to 2147483647
db-14
User monitor 3
-2147483647 to 2147483647
db-16
User monitor 4
-2147483647 to 2147483647
db-18
Analog output monitor YA0
0 to 10000
db-19
Analog output monitor YA1
0 to 10000
db-20
Analog output monitor YA2
0 to 10000
db-21 to
db-23
Reserved
-
Monitors Related to PID Function
Code
Name
Data range
db-30
PID1 feedback data 1 monitor
0.00 to 100.00 (%)
(adjustable in [AH-04][AH-05][AH-06])
db-32
PID1 feedback data 2 monitor
db-34
PID1 feedback data 3 monitor
db-36
PID2 feedback data monitor
0.00 to 100.00 (%)
(adjustable in [AJ-04][AJ-05][AJ-06])
db-38
PID3 feedback data monitor
0.00 to 100.00 (%)
(adjustable in [AJ-24][AJ-25][AJ-26])
db-40
PID4 feedback data monitor
0.00 to 100.00 (%)
(adjustable in [AJ-44][AJ-45][AJ-46])
db-42
PID1 target value monitor after cal-
culation
0.00 to 100.00 (%)(adjustable in [AH-04][AH-05][AH-06])
db-44
PID1 feedback data
db-50
PID1 output monitor
-100.00 to 100.00 (%)
db-51
PID1 deviation monitor
-200.00 to 200.00 (%)
db-52
PID1 deviation 1 monitor
-200.00 to 200.00 (%)
db-53
PID1 deviation 2 monitor
-200.00 to 200.00 (%)
db-54
PID1 deviation 3 monitor
-200.00 to 200.00 (%)
db-55
PID2 output monitor
-100.00 to 100.00 (%)
db-56
PID2 deviation monitor
-200.00 to 200.00 (%)
db-57
PID3 output monitor
-100.00 to 100.00 (%)
db-58
PID3 deviation monitor
-200.00 to 200.00 (%)
db-59
PID4 output monitor
-100.00 to 100.00 (%)
db-60
PID4 deviation monitor
-200.00 to 200.00 (%)
db-61
PID current P gain monitor
0 to 100.00 (%)
db-62
PID current I gain monitor
0.0 to 3600.0 (s)
db-63
PID current D gain monitor
0.00 to 100.00 (s)
db-64
PID feed-forward monitor
-100.00 to 100.00 (%)
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......