9 - 33
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-
5 Mod
bu
s Com
m
u
n
icat
ion
Regi
ster Nu
m
b
er
List
9
9-5-
2 Group d
Register
List
0489h
Trip monitor 9 Factor
dE-19
R
1 to 255
1
048Ah
0489h
Trip monitor 9 Output fre-
quency
-59000 to 59000
0.01(Hz)
048Bh
048Ah
(with sign)
048Ch
048Bh
Trip monitor 9 Output cur-
rent
0 to 65535
0.01(A)
048Dh
048Ch
Trip monitor 9 P-N DC volt-
age
0 to 10000
0.1(Vdc)
048Eh
048Dh
Trip monitor 9 Inverter state
0 to 8
*5
1
048Fh
048Eh
Trip monitor 9 LAD state
0 to 5
*5
1
0490h
048Fh
Trip monitor 9 INV control
mode
0 to 11
*5
1
0491h
0490h
Trip monitor 9 Limit state
0 to 6
*5
1
0492h
0491h
Trip monitor 9 Special state
0 to 6
*5
1
0494h
0493h
Trip monitor 9 RUN time
0 to 1000000
1(hr)
0495h
0494h
0496h
0495h
Trip monitor 9 Power ON
time
0 to 1000000
1(hr)
0497h
0496h
0498h
0497h
Trip monitor 9 Absolute time
(year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
0499h
0498h
Trip monitor 9 Absolute time
(day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
049Ah
0499h
Trip monitor 9 Absolute time
(hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-
049Dh
049Ch
Trip monitor 10 Factor
dE-20
R
1 to 255
1
049Eh
049Dh
Trip monitor 10 Output fre-
quency
-59000 to 59000
0.01(Hz)
049Fh
049Eh
(with sign)
04A0h
049Fh
Trip monitor 10 Output cur-
rent
0 to 65535
0.01(A)
04A1h
04A0h
Trip monitor 10 P-N DC volt-
age
0 to 10000
0.1(Vdc)
04A2h
04A1h
Trip monitor 10 Inverter
state
0 to 8
*5
1
04A3h
04A2h
Trip monitor 10 LAD state
0 to 5
*5
1
04A4h
04A3h
Trip monitor 10 INV control
mode
0 to 11
*5
1
04A5h
04A4h
Trip monitor 10 Limit state
0 to 6
*5
1
04A6h
04A5h
Trip monitor 10 Special state
0 to 6
*5
1
04A8h
04A7h
Trip monitor 10 RUN time
0 to 1000000
1(hr)
04A9h
04A8h
04AAh
04A9h
Trip monitor 10 Power ON
time
0 to 1000000
1(hr)
04ABh
04AAh
04ACh
04ABh
Trip monitor 10 Absolute
time (year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
04ADh
04ACh
Trip monitor 10 Absolute
time (day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
04AEh
04ADh
Trip monitor 10 Absolute
time (hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W
Monitor or setting data
Resolution
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......