6 Basic Parameter Settings
6 - 32
High-function General-purpose Inverter RX2 Series User’s Manual
Parameter (Main Body)
Monitor (Main Body)
Internal Arithmetic Block Diagram
Internal processing is schematically drawn.
Item
Parameters
Data
Description
Default
data
Main speed input
source selection,
1st-motor
[AA101]
13
Frequency command from PG option unit
enabled.
01
*1
*1. Default data when default data selection (UB-02) is set to 01.
Pulse train detection
object selection
[ob-10]
00
Used for frequency command
00
Mode selection of
pulse train input
[ob-11]
00
Mode 0: 90° phase difference pulse string
01
01
Mode 1: Forward/Reverse rotation command
and rotation direction
02
Mode 2: Forward rotation pulse string and
reverse rotation pulse string
Pulse train frequency
Scale
[ob-12]
0.05 to
200.0 (kHz)
A pulse string frequency equivalent to the maxi-
mum frequency is given.
25
Pulse train frequency
Filter time constant
[ob-13]
0.01 to 2.00
(sec)
A filter is applied to the input of the pulse string
frequency.
0.1
Pulse train frequency
Bias value
[ob-14]
-100.0 to
100.0(%)
A bias is applied to the input of the pulse string
frequency.
0.0
Pulse train frequency
High Limit
[ob-15]
0.0 to 100.0
(%)
The output of the pulse string frequency input is
limited.
100.0
Pulse train frequency
detection low level
[ob-16]
0.0 to 100.0
(%)
In outputting the pulse string frequency input,
pulses with the frequency lower than the limit is
set to 0.0%.
0.0
Item
Parameters
Data
Description
Pulse string input mon-
itor (option)
[dA-71]
-100.00 to
100.00(%)
Frequency command from pulse string input
(option input A phase / B phase)
1+sT
1
1+sT
1
×
Hz
%
G
1
%
0
100
-100
100
0
10
-100
0
(% )
0
Pulse string
frequency
acquisition
Max. frequency
IM:[Hb105]
SM:[Hd105]
Pulse string frequency scale
G [ob-12]
(0.05kHz-32.00kHz)
Filter time
constant T [ob-13]
(0.01s-2.00s)
Upper limit [ob-15]
(0.00%-100.00%)
Frequency
command
Bias [ob-14]
(-100.00%-100.00%)
Bias, limit, cut
Limit
Cut
Output
Input
Limit
Cut
Lower limit [ob-16]
(0.01%-100.00%)
Frequency command unit
Bias
Pulse string frequency processing block
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......