8 Applied Settings
8 - 136
High-function General-purpose Inverter RX2 Series User’s Manual
Assign the output terminal function 029 [WAC] capacitor life prewarning signal to one of [CC-01] to
[CC-07] that corresponds to the output terminal and output the signal.
The life spans of the capacitors on the circuit board are diagnosed from the temperature inside the
inverter and the energized time.
The state of this signal can be monitored by using the life diagnostic monitor. Refer to
A warning will also be displayed in the display icons on the LCD operator.
Precautions for Correct Use
You are recommended to replace or repair the inverter when a warning about capacitor lives is
generated.
Parameter
This signal will be output when the rotation speed of the inverter’s built-in cooling fan decreases to 75%
or less.
Assign the output terminal function 030 [WAF] cooling fan rotation speed reduction signal to one of
[CC-01] to [CC-07] that corresponds to the output terminal and output the signal.
The signal is output when it is detected that the rotation speed of the cooling fan incorporated in the
inverter has decreased to 75% or less.
The state of this signal can be monitored by using the life diagnostic monitor. Refer to
A warning will also be displayed in the display icons on the LCD operator.
Precautions for Correct Use
• Check the cooling fan for clogging when this signal is output.
• When the Cooling Fan Operation (bA-70) is set to 01 (Enabled during RUN (including 3 min-
utes after power on/stop), this signal will not be output while the fan is stopped.
8-6-11 Capacitor Life Warning Signal (WAC)
Item
Parameter
Data
Description
Output terminal func-
tion selection 11-15
[CC-01] to
[CC-05]
029
The capacitor life prewarning signal (on board)
[WAC] is output.
OFF: No warning
ON: Time to replace the circuit board because the
capacitors has reached their life spans
Relay output terminal
function selection
16A-16C
[CC-06]
Relay output terminal
function selection
AL1-AL0/AL2-AL0
[CC-07]
Life diagnostic monitor
[dC-16]
LL to HH
The monitors become H at the end of the life spans.
The monitor on the right indicates the lives of the
capacitors on the circuit board, whereas that on the
left indicates the life of the cooling fan.
8-6-12 Cooling Fan Life Warning Signal (WAF)
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......