4 - 3
4 Test Run
High-function General-purpose Inverter RX2 Series User’s Manual
4-
2 Sett
ings
and
Com
man
d
s R
equired
fo
r Run
n
in
g th
e Inv
ert
er
4
4-2
Settings and Commands Required
for Running the Inverter
To turn the motor, configure the following settings.
Precautions for Correct Use
This article explains the settings for operation. Carefully read Safety Instructions before han-
dling the inverter.
1
Basic setting for motor
Set the following parameters in accordance with the plate of motor. Set the data indicating the
basic characteristics of motor.
Note See
on page 6-8 for details.
2
Setting for protection of motor
The motor may be burned if a large current keeps on flowing in the motor; the setting therefore
must be performed appropriately.
Note See
6-6 Thermal Protection of Motor (Electronic Thermal)
3
Setting for activating the motor
The voltage output of the inverter requires not only an operation command but also a frequency
command. In the initial state, a main speed command is used as a frequency command.
Note For details, see
6-3 Operation Command Settings
on page 6-19 and
6-4 Frequency Command Settings
Item
Parameter
IM
SM(PMM)
Async.Motor capacity setting, 1st-motor
[Hb102]
[Hd102]
Async.Motor poles setting, 1st-motor
[Hb103]
[Hd103]
Async.Motor Base frequency setting, 1st-motor
[Hb104]
[Hd104]
Async.Motor Maximum frequency setting,
1st-motor
[Hb105]
[Hd105]
Async.Motor rated voltage, 1st-motor
[Hb106]
[Hd106]
Async.Motor rated current, 1st-motor
[Hb108]
[Hd108]
Item
Parameter
Electronic thermal level setting, 1st-motor
[bC110]
Electronic thermal characteristic selection, 1st-motor
[bC111]
Item
Parameter
Main speed input source selection, 1st-motor
[AA101]
Run-command input source selection, 1st-motor
[AA111]
Main Speed reference monitor
[FA-01]
Содержание RX - 2
Страница 1: ...High function General purpose Inverter RX2 Series User s Manual I620 E1 01 3G3RX2...
Страница 54: ...1 Overview 1 22 High function General purpose Inverter RX2 Series User s Manual...
Страница 136: ...2 Design 2 82 High function General purpose Inverter RX2 Series User s Manual...
Страница 592: ...8 Applied Settings 8 192 High function General purpose Inverter RX2 Series User s Manual...
Страница 754: ...11 Options 11 56 High function General purpose Inverter RX2 Series User s Manual...
Страница 794: ...12 Troubleshooting 12 40 High function General purpose Inverter RX2 Series User s Manual...
Страница 919: ......